255
CLOE
PCL/P35 Pin Output
*
*
CHAPTER 12 CLOCK OUTPUT CONTROL CIRCUIT
12.1 Clock Output Control Circuit Functions
The clock output control circuit is intended for carrier output during remote controlled transmission and clock output
for supply to peripheral LSI. Clocks selected with the timer clock select register 0 (TCL0) are output from the PCL/
P35 pin.
Follow the procedure below to output clock pulses.
(1) Select the clock pulse output frequency (with clock pulse output disabled) with bits 0 to 3 (TCL00 to TCL03)
of TCL0.
(2) Set the P35 output latch to 0.
(3) Set bit 5 (PM35) of port mode register 3 (PM3) to 0 (set to output mode).
(4) Set bit 7 (CLOE) of timer clock select register 0 (TCL0) to 1.
Caution
Clock output cannot be used when setting P35 output latch to 1.
Remark
When clock output enable/disable is switched, the clock output control circuit does not output pulses
with small widths (See the portions marked with * in Figure 12-1).