314
CHAPTER 16 SERIAL INTERFACE CHANNEL 0 (
µ
PD78054 Subseries)
(f)
Busy signal (BUSY) and ready signal (READY)
The BUSY signal is intended to report to the master device that the slave device is preparing for data
transmission/reception.
The READY signal is intended to report to the master device that the slave device is ready for data
transmission/reception.
Figure 16-19. BUSY and READY Signals
In SBI, the slave device notifies the master device of the busy state by setting SB0 (SB1) line to the low
level.
The BUSY signal output follows the acknowledge signal output from the master or slave device. It is set/
reset at the falling edge of SCK0. When the BUSY signal is reset, the master device automatically
terminates the output of SCK0 serial clock.
When the BUSY signal is reset and the READY signal is set, the master device can start the next transfer.
Caution
SBI outputs the BUSY signal after BUSY has been cleared until the next falling edge of
the serial clock. If WUP is set to 1 by mistake during this time, BUSY will not be cleared.
Therefore, when setting WUP to 1, do so after clearing BUSY and then making sure that
the SB0 (SB1) pin has gone high.
READY
ACK
SCK0
SB0 (SB1)
BUSY
8
9
Summary of Contents for PD78052
Page 2: ...2 MEMO ...
Page 8: ...8 MEMO ...
Page 16: ...16 MEMO ...
Page 36: ...36 MEMO ...
Page 158: ...158 MEMO ...
Page 174: ...174 MEMO ...
Page 240: ...240 MEMO ...
Page 260: ...260 MEMO ...
Page 340: ...340 MEMO ...
Page 392: ...392 MEMO ...
Page 438: ...438 MEMO ...
Page 482: ...482 CHAPTER 20 REAL TIME OUTPUT PORT MEMO ...
Page 510: ...510 MEMO ...
Page 524: ...524 MEMO ...
Page 560: ...560 MEMO ...
Page 576: ...576 MEMO ...
Page 598: ...598 MEMO ...
Page 602: ...602 MEMO ...