CHAPTER 18 METER CONTROLLER/DRIVER
18.4 Meter Controller/Driver Operations
18.4.1 Basic operation of free-running up counter (MCNT)
The free-running up counter is counted up by the count clock selected by the PCS bit of the timer mode control
register.
The value of MCNT is cleared by RESET input.
The counting operation is enabled or disabled by the PCE bit of the timer mode control register (MCNTC).
Figure 18-6 shows the timing from count start to restart.
Figure 18-6. Restart Timing after Count Stop (Count Start
→
Count Stop
→
Count Start)
Remark
N = 00H to FFH
18.4.2 To update PWM data
Confirm that bit 4 (TENn) of MCMPCn is 0, and then set 8-bit PWM data to MCMPn1 and MCMPn0, and bits
2 and 3 (ADBn1 and ADBn0) of MCMPCn, and at the same time, set TENn to 1.
The data will be automatically transferred to the slave latch when the timer overflows, and the PWM data becomes
valid. At the same time, TENn is automatically cleared to 0.
CLK
MCNT
PCE
0H
1H
2H
1H
2H
3H
4H
N
N + 1
00H
• • •
Count Start
Count Stop
Count Start