214
CHAPTER 18 METER CONTROLLER/DRIVER
Figure 18-2. 1-Bit Addition Circuit Block Diagram
Remark
n = 1 to 4, m = 0, 1
18.2 Meter Controller/Driver Configuration
The meter controller/driver consists of the following hardware.
Table 18-1. Meter Controller/Driver Configuration
Item
Configuration
Timer
Free-running up counter (MCNT): 1 channel
Register
Compare register (MCMPn1, MCMPn0): 8 channels
Control registers
Timer mode control register (MCNTC)
Compare control register n (MCMPCn)
Port mode control register (PMC)
Pulse control circuit
1-bit addition circuit/output control circuit
Remark
n = 1 to 4
(1) Free running up counter (MCNT)
MCNT is an 8-bit free running up counter, and is a register that executes increment at the rising edge of input
clock.
A PWM pulse with a resolution of 8 bits can be output. The duty factor can be set in a range of 0 to 100%.
The count value is cleared in the following cases.
• When RESET signal input
• When counter stops (PCE = 0)
Cautions 1. MCNT executes counting operation from 01H to FFH repeatedly. However, it counts from
00H upon operation start.
2. The PWM output is not output until the first overflow of MCNT.
Internal bus
f
CC
OVF
Compare register
(MCMPnm)
Q
S
R
Q
S
Selector
ADBn1 ADBn0
Compare control register (MCMPCn)
2
Summary of Contents for mPD780973 Series
Page 2: ...2 MEMO ...
Page 66: ...66 MEMO ...
Page 98: ...98 MEMO ...
Page 138: ...138 MEMO ...
Page 164: ...164 MEMO ...
Page 182: ...182 MEMO ...
Page 204: ...204 MEMO ...
Page 244: ...244 MEMO ...
Page 262: ...262 MEMO ...
Page 278: ...278 MEMO ...
Page 290: ...290 MEMO ...