130
CHAPTER 9 8-BIT TIMER/EVENT COUNTERS 2, 3 TM2, TM3
(a) PWM output basic operation
Figure 9-8. PWM Output Operation Timing
(i)
Basic operation (active level = H)
Count clock
TMn
CRn
TCEn
INTTMn
TIOn
00H 01H
FFH 00H 01H 02H
N N+1
FFH 00H 01H 02H
M
00H
N
Active level
Active level
Inactive level
(ii) CRn = 0
Count clock
TMn
CRn
TCEn
INTTMn
TIOn
Inactive level
Inactive level
01H
00H
FFH 00H 01H 02H
N N+1
FFH 00H 01H 02H
M 00H
00H
N+2
(iii) CRn = FFH
TMn
CRn
TCEn
INTTMn
TIOn
01H
00H
FFH 00H 01H 02H
N N+1
FFH 00H 01H 02H
M 00H
FFH
N+2
Inactive level
Active level
Inactive level
Active level
Inactive level
n = 2, 3