I-2 Accessing Power and Performance Data
'call the driver
Dim outparams
set outparams = oipmi.execmethod_("requestresponse",oinparams)
WScript.Echo " Completion Code = 0x" & hex(outparams.Completioncode)
If outparams.Completioncode <> 0 Then
Wscript.Echo " Not supported"
Else
'WScript.Echo " Data LS Byte = 0x" & hex(outparams.ResponseData(1))
'WScript.Echo " Data MS Byte = 0x" & hex(outparams.ResponseData(2))
WScript.Echo " Power Consumption = " & outparams.ResponseData(2)*256 + _
outparams.ResponseData(1) & " watts"
End If
' End Script
Command Line (Example)
C:\VBS> cscript //nologo Power.vbs
Execution Result (Example)
Completion Code = 0x0
Power Consumption = 528 watts
The power consumption is 528 watts.
NOTE:
Power consumption may not be collected depending on power
supply configuration of the server. In such a case, Completion Code is
shown as 0xC1 or 0xCB.
Summary of Contents for Express5800/R120b-1
Page 20: ...Notes on Using Your Server 1 3 3 5 inch disk model...
Page 87: ...3 24 Setting Up Your Server This page is intentionally left blank...
Page 268: ...6 14 Installing and Using Utilities Windows Server 2003...
Page 296: ...7 14 Maintenance This page is intentionally left blank...
Page 350: ...8 54 Troubleshooting When you use a remote console 6 Each tool is selected and it starts...
Page 438: ...9 82 Upgrading Your Server This page is intentionally left blank...
Page 450: ...C 2 IRQ This page is intentionally left blank...
Page 474: ...D 24 Installing Windows Server 2008 R2 4 Activate Windows The Windows activation is complete...
Page 504: ...E 28 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Page 564: ......
Page 566: ...H 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 576: ...I 10 Accessing Power and Performance Data This page is intentionally left blank...
Page 580: ...J 4 Product Configuration Record Table This page is intentionally left blank...