9-48 Upgrading Your Server
11.
Fix the heat sink with four screws.
NOTE:
Temporarily secure the four screws in the order as shown in
the figure below. Then, secure them tightly.
1
3
4
2
12.
Make sure that the heat sink is level with the mother board.
NOTES:
If the heat sink is not level, remove it, and then install it again. The
following probably causes the heat sink not to be level:
– The CPU is not positioned correctly.
– The heat sink is not completely secured with screws.
Do not move the secured heat sink.
13.
Install the components you removed previously.
14.
Set [Reset Configuration Data] on the Advanced menu to "Yes".
This setting is required to change the hardware configuration data. See Chapter 4 for
details.
15.
If the CPUs are additionally installed to configure a multi-processor system, provide the
following settings on Windows.
Select [Device Manager] - [Computer] and check the driver. If the driver is "ACPI single
processor PC", change it to "ACPI multi-processor PC". Restart the server according to
the on-screen message, and update the system. See Chapter 5 for details.
Summary of Contents for Express5800 120Li
Page 16: ...x This page is intentionally left blank ...
Page 54: ...2 26 General Description This page is intentionally left blank ...
Page 180: ...7 12 Maintenance This page is intentionally left blank ...
Page 214: ...8 34 Troubleshooting This page is intentionally left blank ...
Page 277: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 286: ...10 10 Internal Cabling Diagrams This page is intentionally left blank ...
Page 344: ...F 4 Product Configuration Record Table This page is intentionally left blank ...