9-56 Upgrading Your Server
Removal
Remove the DIMM depending on the following procedure.
NOTES:
To remove the defected DIMM, check the error message appearing
in POST or NEC ESMPRO to identify the DIMM socket (group) in
which the defected DIMM is installed.
The server operates only when at least two DIMMs are installed.
1.
See the section "Preparing for Installation and Removal" described earlier to prepare.
2.
Remove the side cover.
3.
Remove the CPU duct cover.
4.
Open the levers at the both ends of the socket for the DIMM to be removed.
The lock is released to allow the DIMM to be removed.
5.
Install the component removed in Step 2.
6.
Turn on the power of the server. Then make sure that any error message does not appear
in POST.
If an error message appears, write down the message and review the error message list in
Chapter 8.
7.
Start the SETUP to select [Advanced]
→
[Memory Configuration]
→
[Memory Retest] on
the menus to clear the error information on the removed DIMM (see Chapter 4).
8.
Set [Reset Configuration Data] on the [Advanced] menu to "Yes."
This is required to update the hardware configuration information. See Chapter 4 for
details.
Summary of Contents for Express5800 120Li
Page 16: ...x This page is intentionally left blank ...
Page 54: ...2 26 General Description This page is intentionally left blank ...
Page 180: ...7 12 Maintenance This page is intentionally left blank ...
Page 214: ...8 34 Troubleshooting This page is intentionally left blank ...
Page 277: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 286: ...10 10 Internal Cabling Diagrams This page is intentionally left blank ...
Page 344: ...F 4 Product Configuration Record Table This page is intentionally left blank ...