8-16 Troubleshooting
POST fails to complete:
T
Is the DIMM board installed?
→
At least one DIMM board is required for operation.
T
Is the memory size large?
→
The memory check may take a few seconds if the memory size is large. Wait for a
while.
T
Did you perform any keyboard or mouse operation immediately after you started the
server?
→
If you perform any keyboard or mouse operation immediately after start-up, POST
may accidentally detect a keyboard controller error and stops proceeding. In such
a case, restart the server once again. Do not perform any keyboard or mouse
operation until the BIOS start-up message appears when you restart the server.
T
Does the server have contains appropriate memory boards or PCI devices?
→
Operation of the server with unauthorized devices is not guaranteed.
Fail to access to internal or external devices (or such devices fail to operate):
T
Are cables properly connected?
→
Make sure that the interface cables and power cord are properly connected. Also
make sure that the cables are connected in the correct order.
T
Is the power-on order correct?
→
When the server has any external devices connected, power on the external
devices first, then the server.
T
Did you install drivers for connected optional devices?
→
Some optional devices require specific device drivers. Refer to the manual that
comes with the device to install its driver.
T
Is BIOS configuration correct?
→
Most PCI devices generally do not require any change to the configuration, but
some boards do require specific settings. Refer to the manual that comes with the
board for details to make correct settings.
→
Some devices connected to the serial, parallel, or USB port may require I/O port
address or operation mode settings. Refer to the manual that comes with the board
for details to make correct settings.
Summary of Contents for Express5800 120Li
Page 16: ...x This page is intentionally left blank ...
Page 54: ...2 26 General Description This page is intentionally left blank ...
Page 180: ...7 12 Maintenance This page is intentionally left blank ...
Page 214: ...8 34 Troubleshooting This page is intentionally left blank ...
Page 277: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below ...
Page 286: ...10 10 Internal Cabling Diagrams This page is intentionally left blank ...
Page 344: ...F 4 Product Configuration Record Table This page is intentionally left blank ...