Upgrading Your Server 9-25
1.
Locate the failing fan by viewing alert message of NEC ESMPRO, system event log, or
POST error code.
2.
Remove the side cover.
3.
Hold the tabs on both sides of the hot swap fan, and pull the hot swap fan out of the fan
unit
.
4.
Insert the new hot swap fan into the fan unit until it is locked with clicks.
5.
Reassemble the removed components.