142
|
ni.com
|
NI 4071 7½-Digit FlexDMM Calibration Procedure
Verification Limits
This section includes the verification limits for DC voltage, AC voltage, 4-wire resistance,
2-wire resistance, DC current, AC current, and frequency for the NI 4071. Compare these limits
to the results you obtain in the
Note
Use the 24-Hour Limits for a post-adjustment verification
only
. Otherwise,
use the 2-Year Limits.
Limits in the following tables are based upon the September 2008 edition of the
NI 4071 Specifications
. Refer to the most recent NI 4071 specifications online at
. If a more recent edition of the specifications is available,
recalculate the limits based upon the latest specifications.
Calibrator uncertainty is included in the 24-hour limit calculations.