7.1 Example
7-11
Mro-tek(config-fx-eth/0/8/1)#
show interface
Interface ID :1
Description :fx-eth interface 1
opt module type :S3
flow control :on
Tlink :linkup
SD :normal
Remote poweroff :normal
fx-eth Tx packets :16
fx-eth Rx packets :1
fx-eth Rx Error packets :0
Mro-tek(config-fx-eth/0/8/1)#
exit
Mro-tek(config-remote/0/8)#
Configure remote E1 interface (The configuration of the 8 E1 interface are the same.)
Enter the E1 interface configuration mode:
Mro-tek(config-remote/0/8)#
interface e1
1
Mro-tek(config-e1/0/8/1)#
Set clock mode to master.
Mro-tek(config-e1/0/8/1)#
clock-mode
master
setup successfully!
Mro-tek(config-e1/0/8/1)#
Enable CRC self-adaptation.
Mro-tek(config-e1/0/8/1)#
crc-auto
enable
setup successfully!
Mro-tek(config-e1/0/8/1)#
View the information of E1 interface.
Mro-tek(config-e1/0/8/1)#
show interface
Interface ID :1
Description :e1 interface 1
Framemode :framed
subspeed
:1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,2
7,28,29,30,31
Clock mode :master
Crc auto :enable
Port enable :enable
Crc status :enable
Alarm status :noalarm
Tx packets :0
Summary of Contents for PINE-16M
Page 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Page 6: ......
Page 9: ...1 1 Chapter 1 Overview...
Page 11: ...2 1 Chapter 2 Using Command Lines...
Page 15: ...3 1 Chapter 3 System Command...
Page 17: ...4 1 Chapter 4 Configuration at Central Site...
Page 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Page 78: ......
Page 79: ...6 1 Chapter 6 Network Protocol Configuration...
Page 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...