background image

USER GUIDE

TB-4162

Screw Terminal Block for the PXIe-4162

This document explains how to install and use the TB-4162 terminal block with a PXIe-4162
source measure unit (SMU) and includes TB-4162 specifications.

The TB-4162 terminal block is used for screw terminal connections with the PXIe-4162 SMU.

Read this document and the documents listed in the additional resources section about
installation, configuration, and operation of this equipment before you install, configure,
operate, or maintain this product. Users are required to familiarize themselves with installation
and wiring instructions in addition to requirements of all applicable codes, laws, and standards.

Caution

 

Observe all instructions and cautions in the user documentation. Using

the model in a manner not specified can damage the model and compromise the
built-in safety protection. Return damaged models to NI for repair.

Attention

 

Suivez toutes les instructions et respectez toutes les mises en garde de la

documentation utilisateur. L'utilisation d'un modèle de toute autre façon que celle
spécifiée risque de l'endommager et de compromettre la protection de sécurité
intégrée. Renvoyez les modèles endommagés à NI pour réparation.

Notice

 

This device is intended for use only with the PXIe-4162 SMU. For more

information about the PXIe-4162, refer to 

ni.com/manuals

.

Contents

Icons.......................................................................................................................................... 2
Getting Started with the TB-4162.............................................................................................2

Kit Contents and Other Equipment...................................................................................2
Installing the TB-4162...................................................................................................... 2

TB-4162 Specifications.............................................................................................................8

Definitions.........................................................................................................................8
Screw Terminal Wiring..................................................................................................... 9
Physical............................................................................................................................. 9
Environmental Guidelines.................................................................................................9

Compliance and Standards......................................................................................................10

Environmental Management........................................................................................... 10
CE Compliance .............................................................................................................. 10
Export Compliance......................................................................................................... 10
Product Certifications and Declarations..........................................................................11

Summary of Contents for TB-4162

Page 1: ...sing the model in a manner not specified can damage the model and compromise the built in safety protection Return damaged models to NI for repair Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation utilisateur L utilisation d un modèle de toute autre façon que celle spécifiée risque de l endommager et de compromettre la protection de sécurité intégr...

Page 2: ...wdriver Flathead screwdriver Wire insulation strippers Wire cutters Visit ni com for more information about the PXIe 4162 Installing the TB 4162 Complete the following steps to install the TB 4162 with a PXIe 4162 and prepare signal connections Before you begin install the PXIe 4162 in a chassis and ensure that all signals are disconnected from the PXIe 4162 if you have not already done so Refer t...

Page 3: ...ert the stripped end of the ground wire into the LO screw terminal and tighten the screw of the screw terminal to a torque of 0 5 Nm 4 lb in b Insert the stripped end of the signal wires into the appropriate terminals and tighten the screws of the screw terminals to a torque of 0 5 Nm 4 lb in Refer to the following pinout signal information and PXIe 4162 pin map to make the appropriate connections...

Page 4: ...11LS 5HI 3HS 5LS NC 5HS 3HI 3LS 4HI 4G 4HS 4LS 5G 3G 7HI 8LS 6HS 6HI 6LS NC 8HS 8HI 7G 7LS 7HS 6G 8G 1 2 3 4 Table 1 TB 4162 Signals and PXIe 4162 Pin Map Screw Terminal Signal PXIe 4162 Pin Connector 1 LO CH 0 11 Output LO 10 CAL Calibration HI 21 NC No connection 2LS CH 2 Sense LO 59 2G CH 2 Guard 60 4 ni com TB 4162 User Guide ...

Page 5: ...G CH 0 Guard 42 0HS CH 0 Sense HI 61 0HI CH 0 Output HI 62 Connector 2 3HI CH 3 Output HI 57 3HS CH 3 Sense HI 56 3G CH 3 Guard 37 3LS CH 3 Sense LO 36 4HI CH 4 Output HI 15 4HS CH 4 Sense HI 14 4G CH 4 Guard 13 4LS CH 4 Sense LO 12 5HI CH 5 Output HI 34 5HS CH 5 Sense HI 33 5G CH 5 Guard 55 5LS CH 5 Sense LO 54 NC No connection Connector 3 NC No connection 8LS CH 8 Sense LO 48 8G CH 8 Guard 49 TB...

Page 6: ...h 9 Sense LO 25 10HI CH 10 Output HI 4 10HS CH 10 Sense HI 3 10G CH 10 Guard 2 10LS CH 10 Sense LO 1 11HI CH 11 Output HI 23 11HS CH 11 Sense HI 22 11G CH 11 Guard 44 11LS CH 11 Sense LO 43 NC No connection c Ensure that none of the stripped wire is outside of the screw terminal 4 Reassemble the TB 4162 a Bundle the wires together under the strain relief and install the strain relief by tightening...

Page 7: ...by tightening the three screws removed in previous steps to a torque of 0 3 Nm 2 7 lb in 5 Connect the TB 4162 to the PXIe 4162 a Align the male D SUB connector on the back of the TB 4162 and the female D SUB connector on the front of the PXIe 4162 and attach b Tighten the thumbscrews on the front of the TB 4162 until the terminal block is secured to the PXIe 4162 TB 4162 User Guide National Instr...

Page 8: ...62 TB 4162 Specifications These specifications apply to the TB 4162 terminal block for use with the PXIe 4162 The PXIe 4162 is a 12 Channel 24 V 100 mA source measure unit SMU Refer to the PXIe 4162 Specifications for more information Definitions Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty 8 ni com TB 4162 Use...

Page 9: ...in Screw terminal torque 0 5 Nm 4 lb in Spacing between screw terminals 3 5 mm 0 14 in Physical Top cover and strain relief screws M 2 5 Top cover and strain relief screw torque 0 3 Nm 2 7 lb in Dimensions 122 mm 74 mm 18 mm 4 8 in 2 9 in 0 7 in Weight 138 g 4 87 oz Environmental Guidelines Notice This model is intended for use in indoor applications only Environmental Characteristics Temperature ...

Page 10: ...he product life cycle all NI products must be disposed of according to local laws and regulations For more information about how to recycle NI products in your region visit ni com environment weee 电子信息产品污染控制管理办法 中国 RoHS 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物 质指令 RoHS 关于 National Instruments 中国 RoHS 合规性信息 请登录 ni com environment rohs_china For information about China RoHS compliance go to ni...

Page 11: ...fications NI DC Power Supplies and SMUs Help PXIe 4162 4163 Calibration Procedure PXIe 4162 Safety Environmental and Regulatory Information Worldwide Support and Services The NI website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application...

Page 12: ...ments EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY...