5.1 Basic configuration of remote inverse multiplexer device
5-2
5.1 Basic configuration of remote inverse
multiplexer device
5.1.1 Configuring fault pass-through function
Command Description
config
Enter the global configuration mode.
remote
0 <1-16>
Enter the remote inverse multiplexer device configuration mode
fault-pass
(enable|disable)
Configure fault pass-through function.
show info
Shows configuration information
This command is only applicable for inverse multiplexer device with electrical interfaces, including PINE-
iE1 and PINE-8.
Example:
Mro-tek#
config
Mro-tek(config)#
remote
0 8
Mro-tek(config-remote/0/8)#
fault-pass
enable
Mro-tek(config-remote/0/8)#
show info
5.1.2 Reset remote device
Command Description
config
Enter the global configuration mode
remote 0
<1-16>
Enter the remote inverse multiplexer device configuration mode.
Reset
Reset the selected remote inverse multiplexer device
Show info
Show the configuration information
This command is applicable for all remote inverse multiplexer devices.
Example:
Mro-tek#
config
Mro-tek(config)#
remote
0 8
Mro-tek(config-remote/0/8)#
reset
Mro-tek(config-remote/0/8)#
show info
Summary of Contents for PINE-16M
Page 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Page 6: ......
Page 9: ...1 1 Chapter 1 Overview...
Page 11: ...2 1 Chapter 2 Using Command Lines...
Page 15: ...3 1 Chapter 3 System Command...
Page 17: ...4 1 Chapter 4 Configuration at Central Site...
Page 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Page 78: ......
Page 79: ...6 1 Chapter 6 Network Protocol Configuration...
Page 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...