Configuring inverse multiplexing channel
4-8
virtual-channel 12 = 12
virtual-channel 12 error shutdown disable
virtual-channel 13 = 13
virtual-channel 13 error shutdown disable
virtual-channel 14 = 14
virtual-channel 14 error shutdown disable
virtual-channel 15 = 15
virtual-channel 15 error shutdown disable
virtual-channel 16 = 16
virtual-channel 16 error shutdown disabl
e
Mro-tek(config)#
Configuring the automatic error shutdown function
Users can Enable or disable the automatic error shutdown function of the specified channel using the
below given commands. Automatic Error shutdown function will disable the virtual channel when error
bits detected on the respective attached E1 links.
Command Description
config
Enter the global configuration mode
virtual-channel
<1-16>
error-
shutdown
{enable|disable}
To enable/disable automatic error shutdown function for
the selected virtual channel.
show virtual-channel
Shows the information of a selected Virtual channel
Example
: disable the automatic error shutdown function of inverse multiplexing channel 1.
Mro-tek#
config terminal
Configuration mode, one conmmand input per time. End with CTRL-Z.
Mro-tek(config)#
virtual-channel 1 error-shutdown
enable
Set Successfully.
Mro-tek(config)#
show virtual-channel
virtual-channel infomation for slot 0:
virtual-channel 1 = 1
virtual-channel 1 error shutdown enable
virtual-channel 2 = 2
virtual-channel 2 error shutdown disable
virtual-channel 3 = 3
virtual-channel 3 error shutdown disable
virtual-channel 4 = 4
virtual-channel 4 error shutdown disable
Summary of Contents for PINE-16M
Page 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Page 6: ......
Page 9: ...1 1 Chapter 1 Overview...
Page 11: ...2 1 Chapter 2 Using Command Lines...
Page 15: ...3 1 Chapter 3 System Command...
Page 17: ...4 1 Chapter 4 Configuration at Central Site...
Page 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Page 78: ......
Page 79: ...6 1 Chapter 6 Network Protocol Configuration...
Page 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...