7.1 Example
7-9
CrcStatus = disable
LocalLoop = normal
RemoteLoop = loopback
CrcAutoNego = enable
Bert = enable
CommunicationMode = disable
AlarmStatus = NONE
ErrorSecond = 0
SeriousErrorSecond = 0
BitErrorRate = 1
EthSendPacketNum = 0
EthReceivePacketNum = 2727487
EthReceiveErrorPacketNum = 11721
RemoteDevId = 1
RemoteE1 = 1
LinkStatus = LinkOK
Mro-tek(config-e1/0/1)#
Procedures to conduct the BER tester and loopback functions
Mro-tek(config-e1/0/1)#
bert
disable
Set Successfully.
Mro-tek(config-e1/0/1)#
no remote-e1-loopback
Set Successfully.
Mro-tek(config-e1/0/1)#
Enable local loopback.
(Note: before the local loopback of the device is enable, please make sure that the
cables connecting to all E1 ports in the channel the specified E1 port belongs to have been pulled out.)
Mro-tek# config
Configuration mode, one command input per time. End with CTRL-Z.
Mro-tek(config)#
interface e1
1
Mro-tek(config-e1/0/1)#
local-e1-loopback
Set Successfully.
Mro-tek(config-e1/0/1)#
bert
enable
Set Successfully.
Mro-tek(config-e1/0/1)#
show interface
e1 interface information:
slot = 0, portid = 1, ifIndex = 0x20041000
ClockMode = master
FrameMode = framed
Timeslot = 1-31
CrcStatus = disable
Summary of Contents for PINE-16M
Page 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Page 6: ......
Page 9: ...1 1 Chapter 1 Overview...
Page 11: ...2 1 Chapter 2 Using Command Lines...
Page 15: ...3 1 Chapter 3 System Command...
Page 17: ...4 1 Chapter 4 Configuration at Central Site...
Page 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Page 78: ......
Page 79: ...6 1 Chapter 6 Network Protocol Configuration...
Page 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...