7.1 Example
7-4
3. Configuring properties of switching
Set the switching mode of switchport 18 corresponding to Ethernet interface 2 to Trunk mode. Vlan 101 is
allowed.
Mro-tek#
config
Configuration mode, one command input per times. End with CTRL-Z.
Mro-tek(config)#
interface switchport
18
Mro-tek(config-eswif/0/18)#
switchport trunk allowed
vlan 101
Set Successfully.
Mro-tek(config-eswif/0/18)#
show interface
switchport information:
slot = 0, portid = 18, ifIndex = 0x7d0412
type = normal
mode = trunk
access( tunnel) vlan id = 118
trunk( hybrid) native vlan id = 1
trunk tag native enable = enable
hybrid mode allowed vlan =
1
hybrid mode untagged vlan =
1
trunk mode allowed vlan =
1 101
protection enable = disable
discarded package = 0
forwarded package = 1
inunicast package = 0
outunicastt package = 0
inbroadcast package = 0
outbroadcast packet = 1
inmulticast packet = 0
outmulticast packet = 0
Mro-tek(config-eswif/0/18)# exit
Mro-tek(config)# show vlan
state of vlan 1: active
port 18(normal) : trunk
state of vlan 101: active
port 1(normal) : dot1q_tunnel
port 18(normal) : trunk
Summary of Contents for PINE-16M
Page 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Page 6: ......
Page 9: ...1 1 Chapter 1 Overview...
Page 11: ...2 1 Chapter 2 Using Command Lines...
Page 15: ...3 1 Chapter 3 System Command...
Page 17: ...4 1 Chapter 4 Configuration at Central Site...
Page 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Page 78: ......
Page 79: ...6 1 Chapter 6 Network Protocol Configuration...
Page 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...