The configuration of central site E1 interface of PINE-16M
4-2
The configuration of central site E1 interface of
PINE-16M
Configure the master/slave mode of the clock of E1 interface
Command Description
config
Enter the global configuration mode
interface e1
<1-16>
To Select a specific E1 interface at central site PINE-16M
clock-mode
(master|slave)
To configure the clock mode of a selected E1 interface
show interface
Shows the configuration information of the selected E1
interface
Example:
Mro-tek#
config
Mro-tek(config)#
interface e1
1
Mro-tek(config-e1/0/1)#
clock-mode
master
Set Successfully.
Mro-tek(config-e1/0/1)#
Enable or disable the CRC check of the E1 interface
Command Description
config
Enter the global configuration mode
interface e1
<1-16>
To select a specific E1 interface at central site PINE-16M
crc-auto
(enable|disable)
To enable or disable the CRC check of the selected E1 interface
show interface
Shows the configuration information of the selected E1
interface.
If the frame mode of E1 interface is unframed, the enabling of the CRC check will be ineffective.
Example:
Mro-tek#
config
Mro-tek(config)#
interface e1
1
Mro-tek(config-e1/0/1)#
crc-auto
enable
NOTE: this config should be invalid if e1 frame-mode is unframed!
Set Successfully.
Mro-tek(config-e1/0/1)#
Summary of Contents for PINE-16M
Page 1: ...2010 All Rights Reserved PINE 16M Configuration Guide...
Page 6: ......
Page 9: ...1 1 Chapter 1 Overview...
Page 11: ...2 1 Chapter 2 Using Command Lines...
Page 15: ...3 1 Chapter 3 System Command...
Page 17: ...4 1 Chapter 4 Configuration at Central Site...
Page 69: ...5 1 Chapter 5 Configuration of remote inverse multiplexer device...
Page 78: ......
Page 79: ...6 1 Chapter 6 Network Protocol Configuration...
Page 89: ...7 1 Chapter 7 Example of the Configuring PINE 16M...