the nozzle forward until it just touches the mold as shown below.
Clevis link touching stop pin
Nozzle touching mold
6. Use the [
F3
] button to move the carriage so there is a 1-3 mm (1/16-
1/8 in.) gap between the nozzle and the manifold inlet.
7. Use the adjuster screw to move the nozzle forward until it just touches the
manifold inlet as shown in Figure 9-3.
IMPORTANT
Note the gap between the clevis link and the stop pin. The clevis link should
be within 0 - 3/16 in. of the stop pin. On EM1 models the clevis link should
be visible in the 10mm window but not completely covering it. This is the
reference position.
Clevis link 1-5 mm away
from stop pin
Nozzle touching
mold
Figure 9-3 Nozzle touching mold
8. Set carriage home position following procedure “9.17 Nozzle Protrusion
Adjustment - Automatic Adjustment” on page 9-17.
9. Tighten the clamping screw. Use the controller (i.e. buttons F3 and F4) to
move the carriage as required.
9-16
E-Multi User Manual
MAINTENANCE
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.