A more detailed water quality specification is found in “Section 16 - Water
Quality” on page 16-1. The values in “Table 7-2 Basic Water Quality
Specification” on page 7-7 represent conditions that will prevent most
problems associated with poor water quality. These recommended values do
not guarantee that corrosion will not occur.
Figure 7-10
Water quality specification tag on E-Multi
7.6.4 Coolant and Additives
CAUTION
Damage caused by corrosion or condensation is not covered under
warranty.
CAUTION
If the closed loop system volume is small, use a packaged ready made
preserved cooling water kit which contains corrosion and microbiological
inhibitors. Dow Chemical Company’s “DOWFROST” Heat Transfer Fluid is
recommended.
7-8
E-Multi User Manual
SYSTEM SETUP
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.