11.6.1 Install onto an Injection Molding Machine
1. Lift the assembly into place above the injection molding machine’s
stationary platen. Install all adapter plate mounting screws and torque in a
crosswise pattern. See “Screw Torque Specifications” on page 9-1.
2. Install the controller and complete all system connections.
NOTE
The E-Multi Radial controller and systems connection procedure is
very similar the standard E-Multi controller connection procedure. See
“Controller Installation” on page 6-3 and “System Setup” on page 7-1.
Note that the E-Multi Radial has an additional set of cables for the carriage
axis servo motor, and the cables are routed though two cable tracks.
3. Install the barrel heats connector. Route the cables through the cable
track as shown in Figure 11-7.
Figure 11-7 Install the barrel heats connector
4. Attach the servo motor cables. Route the cables through the cable track
Figure 11-8 Attach the servo motor cables
11-9
E-MULTI RADIAL OPTION
E-Multi User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.