DT series
127
BE-801372.01-Digital_clocks_manual-221114
©MOBATIME
•
Hang the Master part on second side of the console and tighten four screws on the back
side.
•
Connect the Master‑Slave power cable, use brown wire for L, white wire for N and green wire for PE
terminals.
ď
Be careful not to swap the terminals.
•
Connect the Master‑Slave data cable, use green wire for GND and brown wire for TxD terminals
on JP4 connector.
ď
Be careful not to swap the terminals.
•
Arrange all incoming cables to appropriate length and connect them to the appropriate terminals
on the PCB or to powering terminal block; see the description of the connectors and observe
the correct polarity where necessary.
•
Fix the cables with the holder in correct positions in order to maintain regular spacing
between the cables in the area of passing through sealing; use appropriate force to not to damage
the cables insulation.
•
Configure the position of DIP switch according to used synchronization signal (applies only for DCF,
MOBALine, polarized impulse line or IRIG‑B)
•
Mount back the connector cover.
•
Tilt the display parts into vertical position and fix them by locking screws.
Note: Smaller models can have only one Master‑Slave connecting cable with cannon connectors.