Configure the position of DIP switch according to used synchronization signal (applies only for DCF,
MOBALine, polarized impulse line or IRIG‑B)
•
Apply the power and check if the display works correctly.
•
Close the front window and secure it using two locks (turn by 90° anticlockwise) on the bottom
of the display body frame.
•
Dismount the mounting eyes and screw‑in the delivered covering Allen screws.
7.9.4.3 Double sided DSC.100–DSC.320
•
The double sided clock consists of the displaying part (Slave), control part (Master) and the wall
bracket mounting console, both parts are linked via one cable.
•
The clock is delivered as a one unit
(both parts are mounted on the console).
•
If the console has the bottom cover, remove it (5x M4 screw) first, bottom cover is attached
to the console by steel wire (captive cover).
•
Unscrew locking screws and put clock parts into fully tilted out positions.
•
Dismantle the back connector cover on the Master part, the cover incorporates gap with sealing
for passage of cables into the clock.
•
Disconnect the Master‑Slave connecting cable.
•
Release four Allen screws on back side of the clocks and take out the both clock parts
from the console.
•
Drill appropriate number of anchoring holes in the wall for wood‑type screws of 10‑12 mm diameter.
Use the mounting console as a template.
•
Push all incoming cables (power, temperature, synchronization) through the upper tube
of the console and through the oval hole, then mount the console on the wall.
• Put both sides into a fully tilted out positions.
•
Hang the Slave part on one side of the console and tighten the four screws on the back side
of the clock part.
•
Hang the Master part on opposite side of the console and tighten the four screws on the back side
of the clock part.
•
Connect the Master‑Slave cable.
•
Arrange all incoming cables to appropriate length and connect them to the appropriate terminals
on the PCB. See the description of the connectors.
ď
Observe the right polarity where necessary.
•
Fix the cables with the holder in correct positions on order to maintain regular spacing between
the cables in the area of passing through sealing. Use appropriate force to not to damage the cables
insulation.
•
Configure the position of DIP switch according to used synchronization signal (applies only for DCF,
MOBALine, polarized impulse line or IRIG‑B)
•
Mount back the connector cover.
•
Tilt the clock parts into vertical position and fix them by locking screws.
•
Mount back the bottom cover if delivered.
7.9.5
Cable connection
2
2
2
3
4
10
TEMP
+
T1
-
T2
TEMP
+
T1
-
T2
NC
NO
COM
A
B
GND
TEMP
+
T1
-
T2
1
IN+
IN-
DC OUT
-
DC OUT+
L
N
red
blue
white
blue
white
red
TEMP wire connection – 1 or 2 temperature sensors
CTRL wire connection
(stopwatch control connects to TEMP connector)
brown
white
green
RELAY wire connection
RS 485 wire connection
brown
white
brown
white
green
POWER connection
brown
white
green
brown
yellow
white
green
Installation LINES / DC OUT wire connection