TZI series
129
BE-801372.01-Digital_clocks_manual-221114
©MOBATIME
7.10.5
Cable connection
2
red
2
2
3
L
N
4
A
B
GND
TEMP
+
T1
-
T2
TEMP
+
T1
-
T2
TEMP
+
T1
-
T2
1
IN+
IN-
DC OUT
-
DC OUT+
brown
white
POWER connection
brown
white
green
red
blue
white
blue
white
red
TEMP wire connection – 1 or 2 temperature sensors
CTRL wire connection
(stopwatch control connects to TEMP connector)
brown
white
green
brown
yellow
white
green
Installation LINES / DC OUT wire connection
RS 485 wire connection
7.11
TZI
7.11.1
Description
Basic features
•
digits of 45 (only for TZI.C), 57 or 100 mm height, which corresponds to readability distance of 20,
25 or 40 m
•
digits in red, pure green blue, yellow, and white color
• possibility of different color for each row
•
display composed of 7‑segment LEDs
•
manual or automatic adjustment of the luminosity of LED diodes
•
customer choice of time zone location and legend style (max. number of time zones is 8)
•
LNx option for configurable location name – character size 45/71 mm
•
time display format in four digits (HH : MM) or six digits format (HH : MM : SS), 12 or 24‑hour cycle
•
AM/PM indication for 12‑hour cycle
•
for model TZI.C display of seconds can be switched off
Mechanic
•
clock frame made of anodized aluminium profiles in black or silver color, powder coated, any other
RAL color on request
•
anti‑reflection front cover made of plexiglass
•
horizontal or vertical (not for TZI.C) layout
• single sided design
•
wall mounting or ceiling suspension
•
protection degree IP 40
• working temperature -5 to +55 °C
Synchronization
•
autonomous operation with internal quartz time base
•
accuracy ±0.1 s/day without synchronization (after 24 hours of synchronization at constant
temperature)
•
slave clock operation with synchronization by MOBATIME serial code, MOBALine, DCF 77, impulse
line or by IRIG‑B, mains powered
•
NTP multicast or unicast synchronization, Ethernet or WiFi network, mains powered
•
RTC backup with supercapacitor (lithium battery on request)
Configuration
• setting of the clock parameters and time by means of IR remote control
Networkconnectionoptions
•
IPv4 and IPv6 support
•
DHCPv4, DHCPv6 / manual configuration of the clock parameters or configuration via web interface
•
DHCPv4, DHCPv6 private strings allow easy configuration of the clock parameters when connected