7.3
DC
7.3.1
Description
Basic features
•
digits of 20, 57, 75, 100, 180 or 250 mm height, which corresponds to readability distance of 9, 25,
32, 40, 70 or 100 m.
•
digits in red, pure green blue, yellow, white and green color
•
display composed of 7‑segment LEDs (SMD LEDs for certain models on request)
•
manual or automatic adjustment of the luminosity of LED diodes
•
altering time, date and temperature display with adjustable time period
•
time display format in four digits (HH : MM) or six digits (HH : MM
SS
or HH : MM : SS), 12 or 24‑hour
cycle
•
date display format in four digits (DD. MM.) or six digits (DD. MM.
YY
or DD. MM. YY)
•
AM/PM indication for 12‑hour cycle (not available for DC.20)
•
temperature display in °C or °F (providing the temperature sensor is connected)
•
TEMP connector is used to connect temperature sensors or stopwatch control
Mechanic
• clock frame made of anodized aluminium in black or silver color, powder coated
•
anti‑reflection front cover made of plexiglass
• single or double sided design
•
wall mounting (only for single sided design), ceiling suspension or wall bracket mounting
•
panel or rack mounting (DC.20)
•
push buttons placed on the upper side of the clock frame
•
protection degree IP 40 (IP 54 on request)
• working temperature 0 to +50 °C
Synchronization
•
autonomous operation with internal quartz time base
•
accuracy ±0.1 s/day without synchronization (after 24 hours of synchronization at constant
temperature)
•
NTP multicast or unicast synchronization, Ethernet or WiFi network, PoE or mains powered
•
slave clock operation with synchronization by MOBATIME, serial code, MOBALine, DCF, impulse line
or by IRIG‑B, mains powered
•
RTC backup with supercapacitor (lithium battery on request)
Configuration
•
setting of the clock parameters and time / date by means of push buttons or IR remote control
Networkconnectionoptions
•
IPv4 and IPv6 support
•
DHCPv4, DHCPv6 / manual configuration of the clock parameters or configuration via web interface
•
DHCPv4, DHCPv6 private strings allow easy configuration of the clock parameters when connected
to LAN