MENU
23
BE-801372.01-Digital_clocks_manual-221114
©MOBATIME
2.3.5.1 SEN1 / SEN2 / SEN3 / SEN4 submenus
ct
submenu for setting the temperature correction
-d.d
setting of the displayed temperature
correction on display
- = negative correction value
d.d = value of correction set digit by digit,
the range of each digit is 0–9
range: ‑9.9 ÷ 9.9 °C
cH
submenu for setting the humidity correction
-d.d
setting of the displayed humidity
correction on display
- = negative correction value
d.d = value of correction set digit by digit,
the range of each digit is 0–9
range: ‑9.9 ÷ 9.9
cP
submenu for setting the pressure correction
-ddd
setting of the displayed pressure
correction on display
- = negative correction value
ddd = value of correction set digit by digit,
the range of each digit is 0–9
range: ‑999 ÷ 999
Pt
submenu for setting the preset temperature value
ddd
setting of the preset temperature value
dd.d = preset value set digit by digit, the range
of each digit is 0–9
range: ‑99 ÷ 999
–.d
setting of the preset temperature value
decimal part
d = value
range: 0 ÷ 9
PH
submenu for setting the preset humidity value
dd
setting of the preset humidity value
dd.d = preset value set digit by digit, the range
of each digit is 0–9
range: 0 ÷ 9
–.d
setting of the preset humidity value
decimal part
d = value
range: 0 ÷ 9
PP
submenu for setting the preset pressure value
dddd
setting of the preset pressure value
dd.d = preset value set digit by digit, the range
of each digit is 0–9
range: 0 ÷ 9999
–.d
setting of the preset pressure value
decimal part
d = value
range: 0 ÷ 9