Local time calculation
33
BE-801372.01-Digital_clocks_manual-221114
©MOBATIME
3.4 Calculation using time zone entries preconfigured
by MOBA‑NMS software
Item
Function
Description
o1
A
NTP protocol uses UTC time zone
o2
A
automatic
o5
0
no time zone server is used
d2
U1–U7
display time and date according to chosen preconfigured
time zone entry, incl. daylight saving time
This setting is suitable for NTP, PoE, WiFi and WiFi5 digital clocks, where several user defined
time zone entries should be used. The time zone entries are preconfigured by means of the MOBA‑NMS
software.
3.5
Calculation according to internal time zone table
Item
Function
Description
o1
0–64
according to the time zone in which source of synchronization
works (e.g. value 2 for DCF in west Europe)
o2
1–8, 11, A
autonomous operation or any type of the synchronizing signal
o4
0
MOBALine time zone is not used
o5
0
time zone server is not used
d2
0–64, U
display time and date by calculation from the UTC time
according to chosen time zone, incl. daylight saving time
This setting is suitable for autonomous digital clocks or in cases where the displayed time is needed
in another time zone than provided by the synchronization source. Displayed time and date calculation
is based on the internal time zone table or on the user‑specific time zone parameters.
See the
chapter 77 with actual Time zone table.