32
BE-801372.01-Digital_clocks_manual-221114
©MOBATIME
3
LOCAL TIME CALCULATION
3.1
Basic setting – control according to source of synchronization
Item
Function
Description
o1
A
time zone is taken over according to the source
of synchronization
o2
2–8, 11, A
synchronization signal type
o4
0
MOBALine time zone is not used
o5
0
time zone server is not used
d2
A
display time and date according to source of synchronization
incl. daylight saving time
This setting is suitable for digital clocks synchronized by a DCF receiver or controlled by a master clock
as slave clock in a time distribution system. The internal time one table is not used.
3.2
Calculation using MOBALine time zones
Item
Function
Description
o1
A
time zone is taken over according to the source
of synchronization, the UTC time calculation is based
on the MOBALine information
o2
4
MOBALine
o4
1–20
selection of the MOBALine time zone
d2
A
display time and date according to chosen MOBALine time zone,
incl. daylight saving time
This setting is suitable for digital clock controlled by a master clock as a MOBALine slave clock in a time
distribution system with possibility to display different MOBALine time zones.
3.3
Calculation using time zone server MOBATIME
Item
Function
Description
o1
A
NTP protocol uses UTC time zone
o2
A
automatic
o5
1–15
selection of the time zone server time zone
d2
A
display time and date according to chosen time zone server
time zone, incl. daylight saving time
This setting is suitable for NTP, PoE, WiFi and WiFi5 digital clocks controlled by MOBATIME NTP servers
which supports the time zone server functionality.