7.2.4
Mounting
7.2.4.1
Single sided
•
Prepare 2 holes in the wall by hinges pitch on the backside of the clock.
• Insert the dowels to the prepared holes and screw the appropriate screws into them.
• Remove the screws on the bottom of the clock. Remove the bottom cover and plexiglass.
•
Except PoE variant use the power cable of at least 3 x 0.5 mm
2
(double isolation), maximal
3 x 1.5 mm
2
(double isolation).
•
Thread the cable(s) through the grommet and hang the clock on the prepared screws in the wall.
•
Cut the cable(s) to the appropriate length and connect the wires to corresponding terminals
or crimp the RJ45 jack to the Ethernet cable respectively.
•
Mount the plexiglass and bottom cover.
7.2.4.2
Double sided
•
First, prepare the 4 holes in the ceiling or wall by bracket flange pitch.
•
Insert the dowels to the prepared holes and fix them into the ceiling (or wall) using appropriate
screws.
•
Remove the screws on the bottom of the Master clock. Remove the bottom cover
and plexiglass.
•
Except PoE variant use the power cable of at least 3 x 0.5 mm
2
(double isolation), maximal
3 x 1.5 mm
2
(double isolation).
•
Cut the cable(s) to the appropriate length and connect the wires to corresponding terminals
or crimp the RJ45 jack to the Ethernet cable respectively.
•
Connect the cable from Slave clock to Master clock.
•
Mount the plexiglass and bottom cover.