MENU
11
BE-801372.01-Digital_clocks_manual-221114
©MOBATIME
2.3
The clock MENU tables
2.3.1
MENU
Program item
Function
Description
dISP
display of time, date, temperature
enter the submenu (d menu)
SYNC
synchronization
enter the submenu (o menu)
NEt
network parameters
enter the submenu (n menu)
SEN1, SEN2
SEN3, SEN4 only
for DT
sensors – 1
st
–4
th
temperature
(temperature, combined)
enter the submenu (t menu)
StoP
stopwatch
enter the submenu (h menu)
tIME
setting of time and date
enter the submenu for time and date
setting
SYSt
system menu
enter the submenu (c menu)
r_._
(e.g. r6.17)
software version
PRINT-SEARCH
If value in MENU tables contains "*", it means the item has accessible submenu.
Example:
Item
Function
Range
(default values are printed in
bold
)
n4
IP address
IP
*
edit IPv4 network parameters in manual
setting mode or display parameters
assigned by DHCPv4
Chevron-double-down
Submenu for displaying a edit IPv4 address
A
1
st
octet IPv4 address
0–255
set digit by digit
b
2
nd
octet IPv4 address
0–255
set digit by digit
C
3
rd
octet IPv4 address
0–255
set digit by digit
d
4
th
octet IPv4 address
0–255
set digit by digit
2.2
MENU navigation scheme using the remote controller
MAIN SCREENS
TIME
DATE
SENSOR 1
SENSOR 2
SENSOR 3 (DT)
SENSOR 4 (DT)
MENU
dISP
SYNC
NEt
SEN1–4
StoP
tIME
r0.01
SYSt
dISP
d1: 1
d2: 3
d3: 0
d1: 1
d2: 3
d3: 0
d2: 3
A 1 92
A19 2
NEt
n1: 0
n2: 3
n3: IP
n4: Su
n5: Gt
IP
A 192
b 168
C 000
d 012
A1 9 2
A 1 92
A19 2
A1 9 2
dISP
>>
>>
>>
<<
<<
<<
MENU
OK
OK
ESC
OK
ESC
OK
OK = SAVE
OK = SAVE
ESC
ESC
>>
<<
>>
>>
OK
OK
OK
<<
<<
–
+
>>
TIMER
Increasing / decreasing value
Example of setting dISP MENU:
Example of setting NEt MENU:
Increasing / decreasing value
STOPWATCH DISPLAY