APPENDICES
Appendix 1 Special Relay List
App
- 22
9
P
a
ra
met
e
rs
10
Device
Exp
la
n
at
ion
11
CP
U
M
odu
le
P
ro
cessi
ng
Ti
m
e
12
P
roc
e
d
ure
f
or W
rit
in
g
P
rog
ra
m t
o CP
U Mo
du
le
A
p
pe
nd
ic
e
s
In
de
x
ACPU
Special
Relay
Special
Relay after
Conversion
Special
Relay for
Modification
Name
Meaning
Details
Corresponding
CPU
M9200
SM1200
–
ZNRD instruction
(LRDP instruction
for ACPU)
reception (for
master station)
OFF : Not accepted
ON : Accepted
• Depends on whether or not the ZNRD (word device read)
instruction has been received.
• Used in the program as an interlock for the ZNRD
instruction.
• Use the RST instruction to reset.
QnA
M9201
SM1201
–
ZNRD instruction
(LRDP instruction
for ACPU)
completion (for
master station)
OFF : Not completed
ON : End
• Depends on whether or not the ZNRD (word device read)
instruction execution is complete.
• Used as a condition contact for resetting M9200 and
M9201 after the ZNRD instruction is complete.
• Use the RST instruction to reset.
M9202
SM1202
–
ZNWR instruction
(LWTP instruction
for ACPU)
reception (for
master station)
OFF : Not accepted
ON : Accepted
• Depends on whether or not the ZNWR (word device
write) instruction has been received.
• Used in the program as an interlock for the ZNWR
instruction.
• Use the RST instruction to reset.
M9203
SM1203
–
ZNWR instruction
(LWTP instruction
for ACPU)
completion (for
master station)
OFF : Not completed
ON : End
• Depends on whether or not the ZNWR (word device
write) instruction execution is complete.
• Used as a condition contact to reset M9202 and M9203
after the ZNWR instruction is complete.
• Use the RST instruction to reset.
M9204
SM1204
–
ZNRD instruction
(LRDP instruction
for ACPU)
reception (for local
station)
OFF : Not completed
ON : End
• On indicates that the ZNRD instruction is complete at the
local station.
M9205
SM1205
–
ZNWR instruction
(LWTP instruction
for ACPU) recep-
tion (for local
station)
OFF : Not completed
ON : End
• On indicates that the ZNWR instruction is complete at the
local station.
M9206
SM1206
–
Host station link
parameter error
OFF : Normal
ON : Abnormal
• Depends on whether or not the link parameter setting of
the host is valid.
M9207
SM1207
–
Link parameter
check results
OFF : Match
ON : Mismatch
• Depends on whether or not the link parameter setting of
the master station in tier two matches that of the master
station in tier three in a three-tier system.
(Valid for only the master station in a three-tier system.)
M9208
SM1208
–
Sets master
station B and W
transmission range
(for lower link
master stations
only)
OFF : Transmits to tier2 and
tier 3
ON : Transmits to tier2 only
• Depends on whether or not the B and W data controlled
by higher-link master station (host station) is sent to lower-
link local stations (tertiary stations).
When SM1208 is OFF............ B and W of host station is
sent to tertiary stations.
When SM1208 is ON ............. B and W of host station is
not sent to tertiary stations.
M9209
SM1209
–
Link parameter
check command
(for lower link
master stations
only)
OFF : Executing the check
function
ON : Check non-execution
• Set to ON not to match B and W of the higher and lower
links.
• When SM1209 is ON, the link parameters of the higher
and lower link are not checked.
• When SM1209 is OFF, the link parameters of the higher
and lower link are checked.
M9210
SM1210
–
Link card error (for
master station)
OFF : Normal
ON : Abnormal
Control is performed depending on whether the link card
hardware is faulty or not.
M9211
SM1211
–
Link module error
(for local station
use)
OFF : Normal
ON : Abnormal
Control is performed depending on whether the link card
hardware is faulty or not.
M9224
SM1224
–
Link status
OFF : Online
ON : Offline,station-to-
station test, or self-
loopback test
Depends on whether the master station is online or offline or
is in station-to-station test or self-loopback test mode.
M9225
SM1225
–
Forward loop error
OFF : Normal
ON : Abnormal
Depends on the error condition of the forward loop line.
M9226
SM1226
–
Reverse loop error
OFF : Normal
ON : Abnormal
Depends on the error condition of the reverse loop line.
M9227
SM1227
–
Loop test status
OFF : Not being executed
ON : Forward or reverse
loop test execution
underway
Depends on whether or not the master station is executing a
forward or a reverse loop test.
M9232
SM1232
–
Local station
operation status
OFF : RUN or STEP RUN
status
ON : STOP or PAUSE
status
Control is performed depending on whether a local station is
in the STOP or PAUSE mode.
M9233
SM1233
–
Local station error
detect status
OFF : No errors
ON : Error detection
Depends on whether or not a local station has detected an
error in another station.