6.11 Monitor Function
6.11.4 Executional conditioned device test
6
- 73
1
O
verv
iew
2
Per
fo
rma
nce
S
p
ecifica
tio
n
3
S
equ
en
ce P
ro
g
ra
m
Co
nfig
ura
tio
n a
nd
E
xecut
io
n Co
nd
iti
o
ns
4
I/O N
unb
er
Assig
n
m
e
nt
5
Me
mor
ie
s a
nd
File
s
Ha
nd
led
by CP
U Mo
du
le
6
Func
tions
7
Co
mmu
nic
a
tion
us
in
g
bu
ilt
-i
n E
th
e
rne
t po
rt
s o
f
CP
U mod
u
le
8
Co
mm
un
icatio
n
w
ith
Int
e
lli
ge
nt
Fun
ction
Mo
du
le
(5) Precautions
(a) Operating function from multiple GX Developer
Executional conditioned device test setting can be registered in the same CPU
module from multiple GX Developer connected via network.
Note, however, that multiple executional conditioned device test settings are
registered with the same device name in the same step, the registration data will
be overwritten.
When registering executional conditioned device data setting from multiple GX
Developer, update the data first by clicking the
button, and then register
the setting.
(b) Priority
If any of the following functions is set in the same step number that is specified by
the executional conditioned device test setting, the Executional conditioned
device test is given the priority to other functions.
• Monitor condition setting
• Sampling trace function (trace point)
• Sampling trace function (trigger point)
• Scan time measurement (start step)
• Scan time measurement (end step)
(c) Disabling executional conditioned device test settings
Executional conditioned device test setting can be disabled by any of the following
operations, other than by the operation from GX Developer.
• Powering OFF ON the programmable controller
• Performing the reset operation of the CPU module
• Writing program files to the program memory of the CPU module in STOP
state
• Clearing the program memory of the CPU module in STOP state
• Formatting the program memory of the CPU module in STOP state
(d) Executing Online change (Write during RUN)
The module operation will be as follows if the Executional conditioned device test
and Online change (Write during RUN) are executed simultaneously.
1) When the Executional conditioned device test is executed during
execution of the Online change (Write during RUN)
The Online change completes normally. However, the Executional conditioned
device test cannot be executed. The following message box appears. Execute the
function again after the Online change has completed.
Figure 6.47 Message box when Executional conditioned device test is executed
during execution of Online change
Read file