8 - 18 8 - 18
MELSEC-Q
8 DATA COMMUNICATION USING THE PRE-DEFINED PROTOCOL
5) The "Element setting – Conversion variable" screen is displayed.
In the "Send data storage area" field, enter "D300". Click the OK
button.
6) The "Packet setting" screen is displayed.
The packet setting of "Packet name" H7B:RD Operation Mode has
been completed. Click the Close button.
7) The "Protocol setting" screen is displayed.
Repeat the steps 3) to 6) described above to configure the packet
setting of "Packet name" NOR:RD Data(4 Digits Data) and ERR:NAK
Response.
In "Data storage area", enter the following values.
Packet name
Element No.
Element name
Data storage area
specification
2
Inverter Station Number
Enter D200.
NOR:RD Data (4 Digits Data)
3
Read Data
Enter D201.
2
Inverter Station Number
Enter D202.
ERR:NAK Response
3
Error Code
Enter D203.