(2) Available devices
The following devices are available for the dedicated instructions:
Internal devices
Bit
1
Word
File register
Constant
2
X, Y, M, L, F, V, B
T, ST, C, D, W
R, ZR
K, H
1 Word device bit designation can be used as bit data.
Word device bit designation is done by designating Word device . Bit No. .
(Designation of bit numbers is done in hexadecimal.)
For example, bit 10 of D0 is designated as D0.A .
However, there can be no bit designation for timers (T), retentive timers (ST) and
counters (C).
2 Available devices are given in each of the Constant field.