736
15 TYPE CONVERSION FUNCTIONS
15.36 Converting REAL to DINT
Operation error
Error code
(SD0/SD8067)
Description
3401
The single-precision real number in the device specified by (s) is out of the valid range (-2147483648 to 2147483647).
3402
A special number is set to (s).
• The set single-precision real number is not located within the following range.
0, 2
-126
|(s)|< 2
128
• The set device or label value is -0, denormalized number, NaN (not a number), or
.