Precautions
• These instructions occupy three points for each of three devices starting from device number specified by (s1), (s2), and (d)
respectively. Make sure that these devices are not used by other machine controls.
• When using the time value (hour, minute, second) of the built-in real time clock in the CPU module for the operation, use
the TRD(P) operation to read the special register values first. Then specify the word devices where the read values are
stored to each operand.
Operation error
Error code
(SD0/SD8067)
Description
2820
The device range specified by (s1), (s2), and (d) exceeds the corresponding device range.
3405
Any of values specified by (s1) and (s2) is outside the following range.
0 to 23
Any of values specified by (s1)+1, (s2)+1, (s1)+2, and (s2)+2 is outside the following range.
0 to 59