6 BASIC INSTRUCTIONS
6.5 Data Conversion Instructions
285
6
Encoding from 256 to 8 bits
ENCO(P)
These instructions encode the 2
(n)
bits of data from the device specified by (s), and store it in (d).
Setting data
■
Descriptions, ranges, and data types
■
Applicable devices
Processing details
• These instructions store into (d) the binary value corresponding to the bit whose value is 1 in the data with 2
(n)
bits.
• When (n) is 0, no processing is performed, and the contents of the device specified by (d) do not change.
• The bit device is handled as a device storing one-bit data and the word device is handled as a device storing 16-bit data.
• If two or more bits are 1, the higher bit position is processed.
Operation error
Ladder diagram
Structured text
ENO:=ENCO(EN,s,n,d);
ENO:=ENCOP(EN,s,n,d);
Operand
Description
Range
Data type
Data type (label)
(s)
Head device for storing the encode data
Bit/word
ANY_ELEMENTARY
(d)
Device number for storing the encoding result
16-bit signed binary
ANY16
(n)
Valid bit length
1 to 8
16-bit unsigned binary
ANY16
Operand
Bit
Word
Double word
Indirect
specification
Constant
Others
X, Y, M, L,
SM, F, B, SB
U
\G
T, ST,
C, LC
T, ST, C, D,
W, SD, SW, R
U
\G
Z
LC
LZ
K, H
E
$
(s)
(d)
(n)
Error code
(SD0/SD8067)
Description
2820
The device specified by (s) exceeds the corresponding device range.
3401
The entire data from (s) to 2
(n)
number of bits is 0.
(s) is specified as a bit device and (n) is other than 0 to 8.
(s) is specified as a word device and (n) is other than 0 to 4.
(s)
(d)
(n)
1 1 0
(d)
7
0
8
6 5 4 3 2 1 0
0
1 0 0 0 0 0 0
(s)
(Binary value = 6)
Summary of Contents for MELSEC iQ-F FX5 series
Page 1: ...MELSEC iQ F FX5 Series Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 21: ...19 PART 1 PART 1 OVERVIEW Part 1 consists of the following chapter 1 OVERVIEW ...
Page 98: ...96 4 STANDARD FUNCTIONS FUNCTION BLOCKS 4 2 Standard Function Blocks MEMO ...
Page 840: ...838 23 TIME DATA FUNCTIONS 23 4 Division MEMO ...
Page 887: ......