7 APPLICATION INSTRUCTION
7.20 Timing check instruction
601
7
7.20
Timing check instruction
Generating timing pulses
DUTY
This instruction sets user timing clock output destinations (SM420 to SM424 and SM8330 to SM8334) specified by (d) to on
for the number of scans specified by (n1) and to off for the number of scans specified by (n2).
Setting data
■
Descriptions, ranges, and data types
■
Applicable devices
*1
Only SM can be used.
Processing details
• This instruction sets user timing clock output destinations (SM420 to SM424 and SM8330 to SM8334) specified by (d) to on
for the number of scans specified by (n1) and to off for the number of scans specified by (n2).
• Specify SM420 to SM424 (SM8330 to SM8334) in the special relay of the timing clock output destination specified by (d).
• In SM420 to SM424 (SM8330 to SM8334), when one device is turned on, another device is also turned on at the same
time.
• The counted number of scans is stored among SD8330 to SD8334 in accordance with the special relay of the timing clock
output destination specified by (d).
• The counted number of scans stored among SD8330 to SD8334 is reset when the counted value reaches "(n1)+(n2)" or
when the command input (instruction) is set to on.
Ladder diagram
Structured text
ENO:=DUTY(EN,s1,s2,d);
Operand
Description
Range
Data type
Data type (label)
(n1)
Number of scans to be turned on
0 to 65535
16-bit unsigned binary
ANY16
(n2)
Number of scans to be turned off
0 to 65535
16-bit unsigned binary
ANY16
(d)
Special relay of the timing clock output destination
(SM420 to SM424,
SM8330 to SM8334)
Bit
Bit
Operand
Bit
Word
Double word
Indirect
specification
Constant
Others
X, Y, M, L,
SM, F, B, SB
U
\G
T, ST,
C, LC
T, ST, C, D,
W, SD, SW, R
U
\G
Z
LC
LZ
K, H
E
$
(n1)
(n2)
(d)
Special relay (d) for outputting the timing clock
Scan counting device
SM420(SM8330)
SD8330
SM421(SM8331)
SD8331
SM422(SM8332)
SD8332
SM423(SM8333)
SD8333
SM424(SM8334)
SD8334
(n1)
(n2)
(d)
OFF
ON
(n1) scans
(n2) scans
SM420 to SM424
Summary of Contents for MELSEC iQ-F FX5 series
Page 1: ...MELSEC iQ F FX5 Series Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 21: ...19 PART 1 PART 1 OVERVIEW Part 1 consists of the following chapter 1 OVERVIEW ...
Page 98: ...96 4 STANDARD FUNCTIONS FUNCTION BLOCKS 4 2 Standard Function Blocks MEMO ...
Page 840: ...838 23 TIME DATA FUNCTIONS 23 4 Division MEMO ...
Page 887: ......