7 APPLICATION INSTRUCTION
7.7 Real Number Instruction
443
7
Calculating the tangent of single-precision real number
TAN(P)/DTAN(P)
These instructions calculate the tangent of the angle specified by (s), and store the operation result in the device specified by
(d).
The TAN(P) instructions can also be used as DTAN(P).
*1
The TAN instruction is not supported by the ST language. Use TAN of the standard function.
Setting data
■
Descriptions, ranges, and data types
■
Applicable devices
Processing details
• These instructions calculate the tangent of the angle specified by (s), and store the operation result in the device specified
by (d).
• Set the angle data in radians (angle
180).
• The table below shows the related devices.
Precautions
When the angle specified by (s) is
/2 radian or (3/2)
radian, no error occurs because an operation error occurs in a radian
value.
Ladder diagram
Structured text
ENO:=TANP(EN,s,d);
Operand
Description
Range
Data type
Data type (label)
(s)
Angle data or head device number where the angle data is
stored
Single-precision real number
Single-precision real number
(d)
Head device number for storing the operation result
Single-precision real number
Single-precision real number
Operand
Bit
Word
Double word
Indirect
specification
Constant
Others
X, Y, M, L,
SM, F, B, SB
U
\G
T, ST,
C, LC
T, ST, C, D,
W, SD, SW, R
U
\G
Z
LC
LZ
K, H
E
$
(s)
(d)
Device
Name
Description
Condition
Operation
SM700
Carry
The absolute value of the operation result
2
128
The value of (d) is the maximum value (2
128
) of 32-bit real
numbers and the carry flag SM700 turns on.
SM8020
Zero
The operation result is true "0".
(The mantissa part is "0").
The zero flag SM8020 turns on.
SM8021
Borrow
The absolute value of the operation result < 2
-126
The value of (d) is the minimum value (2
-126
) of 32-bit real
numbers and the borrow flag SM8021 turns on.
SM8022
Carry
The absolute value of the operation result
2
128
The value of (d) is the maximum value (2
128
) of 32-bit real
numbers and the carry flag SM8022 turns on.
(s)
(d)
(s)+1
(s)
(d)+1
(d)
TAN ( )
Single-precision real number
Single-precision real number
Summary of Contents for MELSEC iQ-F FX5 series
Page 1: ...MELSEC iQ F FX5 Series Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 21: ...19 PART 1 PART 1 OVERVIEW Part 1 consists of the following chapter 1 OVERVIEW ...
Page 98: ...96 4 STANDARD FUNCTIONS FUNCTION BLOCKS 4 2 Standard Function Blocks MEMO ...
Page 840: ...838 23 TIME DATA FUNCTIONS 23 4 Division MEMO ...
Page 887: ......