7 APPLICATION INSTRUCTION
7.6 Character string operation instruction
387
7
Operation error
Error code
(SD0/SD3067)
Description
2820
The device specified by (s2) exceeds the corresponding device range.
3401
The number of total digits specified by (s1)+1 exceeds 24.
The format specified by (s2) is any value other than "0" or "1".
The total number of digits specified by (s2)+1 is not within the following range in the decimal point format.
When the number of digits of the decimal part is "0": Total number of digits
2
When the number of digits of the decimal part is any value other than "0": Total number of digits
(Number of digits of decimal part + 3)
The total number of digits specified by (s2)+1 is not within the following range in the exponent format.
When the number of digits of the decimal part is "0": Total number of digits
6
When the number of digits of the decimal part is any value other than "0": Total number of digits
(Number of digits of decimal part + +7)
The number of digits of the decimal part specified by (s2)+2 is not within the following range.
In the decimal part format
(Total number of digits - 3)
In the exponent format
(Total number of digits - 7)
When the conversion result exceeds the specified total number of digits
3402
(s1) is not within the following range
0,
2
-126
(s1) <
2
128
The specified device value is denormalized number, NaN (not a number), or
.
3405
The number of digits of the decimal part specified by (s2)+2 is not within the following range.
0 to 7
3406
The device areas that store the character string specified by (d) exceed the corresponding device range.
Summary of Contents for MELSEC iQ-F FX5 series
Page 1: ...MELSEC iQ F FX5 Series Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 21: ...19 PART 1 PART 1 OVERVIEW Part 1 consists of the following chapter 1 OVERVIEW ...
Page 98: ...96 4 STANDARD FUNCTIONS FUNCTION BLOCKS 4 2 Standard Function Blocks MEMO ...
Page 840: ...838 23 TIME DATA FUNCTIONS 23 4 Division MEMO ...
Page 887: ......