7 APPLICATION INSTRUCTION
7.17 Data operation instruction
575
7
Processing details
• These instructions generate CRC value for (n) 8-bit data (unit: byte) starting from a device specified in (s), and store to (d).
The 16-bit conversion mode and 8-bit conversion mode are available for these instructions. For the operation in each
mode, refer to the proceeding pages.
• 16-bit conversion mode (while SM8161 is OFF)
In this mode, the operation is executed for high-order 8 bits (1 byte) and low-order 8 bits (1 byte) of a device specified in (s). The operation result is stored
to one 16-bit device specified in (d).
In the following program, conversion is executed as follows:
Example) (s) = D100, (d) = D0, (n) = 6
Device
Contents of target data
8 bits
16 bits
Device storing data
for which the CRC
value is generated
(s)
Low-order byte
Low-order bits of D100
01H
0301H
High-order byte
High-order bits of D100
03H
(s)+1
Low-order byte
Low-order bits of D101
03H
0203H
High-order byte
High-order bits of D101
02H
(s)+2
Low-order byte
Low-order bits of D102
00H
1400H
High-order byte
High-order bits of D102
14H
(s)+(n)/2-1
Low-order byte
High-order byte
Device storing the
generated CRC value
(d)
Low-order byte
Low-order bits of D0
E4H
41E4H
High-order byte
High-order bits of D0
41H
• 8-bit conversion mode (while SM8161 is ON)
In this mode, the operation is executed only for low-order 8 bits (low-order 1 byte) of a device specified by (s). With regard to the operation result, low-
order 8 bits (1 byte) are stored to a device specified by (d), and high-order 8 bits (1 byte) are stored to a device specified by (d)+1.
In the following program, conversion is executed as follows:
Example) (s) = D100, (d) = D0, (n) = 6
Device
Contents of target data
Device storing data for
which the CRC value
is generated
(s)
Low-order byte
Low-order bits of D100
01H
(s)+1
Low-order byte
Low-order bits of D101
03H
(s)+2
Low-order byte
Low-order bits of D102
03H
(s)+3
Low-order byte
Low-order bits of D103
02H
(s)+4
Low-order byte
Low-order bits of D104
00H
(s)+5
Low-order byte
Low-order bits of D105
14H
(s)+(n)-1
Low-order byte
Device storing the
generated CRC value
(d)
Low-order byte
Low-order bits of D0
E4H
(d)+1
High-order byte
High-order bits of D0
41H
CRC
(s)
(d)
(n)
SM400
SM8161
Command
input
16-bit conversion mode
CRC
(s)
(d)
(n)
SM400
SM8161
Command
input
8-bit conversion mode
Summary of Contents for MELSEC iQ-F FX5 series
Page 1: ...MELSEC iQ F FX5 Series Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 21: ...19 PART 1 PART 1 OVERVIEW Part 1 consists of the following chapter 1 OVERVIEW ...
Page 98: ...96 4 STANDARD FUNCTIONS FUNCTION BLOCKS 4 2 Standard Function Blocks MEMO ...
Page 840: ...838 23 TIME DATA FUNCTIONS 23 4 Division MEMO ...
Page 887: ......