[6-11 Standard Operation Data (Reference Data) ]
- 138 -
HWE14080
GB
Packaged unit model
PUHY-P168T(Y)SLMU
Outdoor unit model
PUHY-P72T(Y)LMU
PUHY-P96T(Y)LMU
Conditions
Ambient temperature
(cooling)
Indoor
DB/WB
26.7°C/19.4°C [80°F/67°F]
Outdoor
35°C/- [95°F/-]
Ambient temperature
(heating)
Indoor
DB/WB
21.1°C/- [70°F/-]
Outdoor
8.3°C/6.1°C [47°F/43°F]
Indoor unit
Number of units connected
Unit
4
Number of units in operation
4
Model
-
36/36/48/48
Piping
Main pipe
m [ft]
5
[16-3/8]
Branch pipe
10
[32-3/4]
Total pipe length
45
[147-5/8]
Fan speed
-
Hi
Refrigerant charge
kg [lbs-oz]
17
[37]
Outdoor unit
Voltage
*1
V
230
Cooling operation
Outdoor unit
Electric current
*1
A
37.9
Compressor frequency
Hz
52
65
LEV open-
ing
Indoor unit
Pulse
325/325/387/387
SC (LEV1)
190
190
LEV2
2100
2100
Pressure
High pressure (after O/S)/Low pressure (before accumulator)
MPa [psi]
2.71/0.90
[393/131]
2.71/0.90
[393/131]
Section
tempera-
tures
Outdoor unit
Discharge (TH4)
°C [°F]
69
[156]
74
[165]
Heat exchanger outlet (TH3)
44
[111]
46
[115]
Accumulator inlet
10
[50]
10
[50]
Accumulator outlet
10
[50]
10
[50]
SCC outlet (TH6)
24
[75]
26
[79]
Compressor inlet
17
[63]
14
[57]
Compressor shell bottom
47
[117]
38
[100]
Indoor unit
LEV inlet
24
[75]
24
[75]
Heat exchanger outlet
10
[50]
10
[50]
Heating operation
Outdoor unit
Electric current
*1
A
40.8
Compressor frequency
Hz
53
71
LEV open-
ing
Indoor unit
Pulse
332/332/406/406
SC (LEV1)
0
LEV2
2100
2100
Pressure
High pressure (after O/S)/Low pressure (before accumulator)
MPa [psi]
2.72/0.66
[395/95]
2.72/0.66
[395/95]
Section
tempera-
tures
Outdoor unit
Discharge (TH4)
°C [°F]
72
[162]
75
[167]
Heat exchanger outlet (TH3)
0
[32]
-2
[28]
Accumulator inlet
0
[32]
-2
[28]
Accumulator outlet
0
[32]
-2
[28]
Compressor inlet
0
[32]
-2
[28]
Compressor shell bottom
40
[104]
40
[104]
Indoor unit
LEV inlet
37
[98]
37
[98]
Heat exchanger inlet
72
[161]
72
[161]
*1. Measurements of current and voltage that are listed in the table above are those of the TLMU model.
Summary of Contents for R410A
Page 1: ......
Page 11: ... 2 HWE14080 GB ...
Page 25: ... 16 HWE14080 GB ...
Page 38: ... 2 6 System Connection Example 29 HWE14080 GB 2 Restrictions ...
Page 57: ... 2 10 Restrictions on Refrigerant Pipes 48 HWE14080 GB ...
Page 59: ... 50 HWE14080 GB ...
Page 71: ... 62 HWE14080 GB ...
Page 95: ... 86 HWE14080 GB ...
Page 121: ... 5 3 Operation Flowcharts 112 HWE14080 GB ...
Page 123: ... 114 HWE14080 GB ...
Page 159: ... 150 HWE14080 GB ...
Page 243: ... 7 8 Error Code Definitions and Solutions Codes 7000 7999 234 HWE14080 GB ...
Page 309: ... 300 HWE14080 GB ...
Page 346: ......