V
Electrical Wiring Diagram ]
- 109 -
HWE09080
GB
(3) PQHY-P72, 96, 120YHMU-A
㧗
1 2
*7
Z24,25
Thermistor
Operation ON signal, Pump Interlock
Discharge pipe temperature
ACC inlet pipe temperature
W
ater inlet temperature
IGBT
temperature
Function setting connector
THHS
TH7
TH5
TH4
TB8
Power supply
Indoor/Heat source transmission cable
Central control transmission cable
T
erminal
block
TB7
TB3
TB1
Subcooled liquid refrigerant temperature
TH6
Pipe temperature
Subcool bypass outlet temperature
TH2
TH3
Outlet temp.detect of heat exchanger for inverter
THINV
W
ater outlet temperature
TH8
Explanation
Symbol
L1
L2
Power Source
ޓ
3~
ޓ
60Hz
ޓ
460V
T
ransformer box
purple
1
2
3
4
CN06
T02
(T
ransformer)
CNTR2
CN07
1
2
3
4
5
6
T03
(T
ransformer)
CNTR3
5
6
2
4
3
1
460V
460V
purple
1
X09
3
6
CN508
black
Unit address
setting
CN504 green
CT12
C31
C33
CN5 red
D1
R5
Z5
1
SV9
CNTR1
12
L1
L2
L2
3
L3
45678
white
TH2
t°
white
red
black
black
white
red
F4 AC 600V 3A
F
C8
F5 AC 600V 3A
F
red
CNIT
yellow
CNS2
t°
1
CN51
12V
Function
setting
SW1
10
1
CN212
CNTYP4 green
F4 AC250V 6.3A
T
R4
F3
F1
Z4
R2
F2
*3
3
2
Compressor ON/OFF output
Error detection output
CN201
Z25
1
4
1
1
1
TH3
Z3
Z2
U
ON
OFF
SW2
10
1
SWU2
LED1
C4
C35
C37
R31
R33
R30
ON
SW3
10
Control Board
TH7
CN40
63HS1
CN41
TH6
t°
t°
TH4
3
2
2
2
1
SW5
LED3:Lit when powered
1
3
4
R32
2
Z1
1
DSA
C10
R34
R35
LEV1
LEV2a
C36
3
C34
SC-V
CT22
SC-U
V
1
CN4 blue
red
1
M
1
LEV2b
t°
black
4
1
3
6
yellow
CN3K
*3
3
M
C3
TB21
C1
R3
3
M
CN1A
5
U
CN2
blue CN3N
5
6
C7
U
4
4
R1
TB1
CN1B
3
TB7 Power
selecting
connector
CN102
3
2
1
2
1
U
TP1
L3
DCL
black
72C
white
red
3
2
1
ON
OFF
1
M-NET
power
supply circuit
1
2
3
C6
M-NET
Board
1
2
1
1
CNAC2 black
CN502
5
Indoor/Outdoor
transmission
cable
INV Board
red
3
CNT01
TB23
L2
L1
1
ON
1
2
1's digit
THHS
1
CNIT red
S
2
1
1
CN990
1
W
TB3
10's digit
OFF
LED2:CPU in operation
5
2
CNS2 yellow
TB7
1
CNDC pink
M1
2
red
6
MS
3~
1
1
t°
C100
*5
3
3
U
1
4
LED1:Power supply to
Indoor/Outdoor transmission line
ZNR01
M2
32
M1
black
Central control
transmission
cable
*6
SC-L1
4
C2
C9
ON
C5
OFF
FT
-N
R5
Motor
(Compressor)
5
2
3
3
1
CN04 red
CN2
3
CN4
X05
2
SC-P2
P
1
CN21
1
CN202 red
TH5
N
CN1
M2
2
TP2
LED1:Normal operation(Lit)
/ Error(Blink)
2
CN503 blue
5
X04
4
*4
SC-W
U
C32
SC-L3
CH1
1
CN506
1
2
CN72 red
3
P
63H1
CN801 yellow
1
2
F1,F2,F3 AC250V 6.3A
T
2
1
OFF
SW4
10
CNT02
1
CN3D
4
3
2
1
21
CPU power
supply circuit
CNAC red
2
1
F01 AC250V 3.15A
T
1
t
CN507 red
ON
OFF
10
SWU1
white
CN213 red
SC-L2
3
Z24
7
4
3
2
1
2
1
1
CN83
3
1
3
1
CNTYP5 green
21S4a
U
X02
X03
5
1
7
CN4
CN6
IGBT
4
SC-P1
FT
-P
black
C30
red
Diode Bridge
CT3
72C
C1
CN2
R1
black
TB22
3
RSH1
CN102
3
R6
C17
1
1
63LS
ZNR1
U
L
Noise
Filter
X08
3
1
CN6 yellow
red
SV4a
X07
3
5
6
4
3
2
CNL
V
A
CNL
VB
red
CNL
VC
red
1
2
3
4
5
6
white
black
SV1a
1
G
Ground
6
5 4 3 2 1
6
G
5 4
G
3 2
1
2
L1
L2
L3
1
CN215 black
L3
MF1
Fan motor(Radiator panel)
SV1a
SV4a,b,d
HIC bypass,Controls refrigerant flow in HIC circuit
Heat exchanger capacity control
For opening/closing the bypass circuit under the O/S
LEVINV
Heat exchanger for inverter
SV7a,b
Heat exchanger capacity control
For opening/closing the bypass circuit
LEV2a,b
Pressure control,Refrigerant flow rate control
<Symbol explanation>
63HS1
SV9
21S4a
4-way valve
Explanation
Symbol
63H1
63LS
Pressure sensor
Pressure switch
High pressure protection for the heat source unit
High pressure
Low pressure
72C
Magnetic relay(inverter main circuit)
Current sensor(AC)
Crankcase heater(for heating the compressor)
CH1
1
CT12,22,3
Solenoid valve
Linear expansion valve
LEV1
DCL
DC reactor
Power
failure
detection
circuit
1 2 3 4 5 6
orange
3
Pump Interlock
Operation
ON signal
*7
TB8
1
blue
4
yellow
4
1
red
CNAC4
CNPW
blue
2
2
5
61
3
CNOUT1 yellow
4
CNOUT2 yellow
5
X12
1
X06
M
㨪
X14
6
CN510 yellow
blue CN63PW
4
2
1
1
5
MF1
SV7a
6
CN509 blue
THINV
t°
CNTYP1 black
1
2
SV7b
t°
TH8
LEVINV
SV4d
1
SV4b
1
2
M
1
CN992 yellow
2
4
75
CNL
VE
6 5 4 3 2 1
5
RELA
Y
Board
CN
TYP
black
3
1
CNTYP2 black
1
3
*1.Single-dotted lines indicate wiring not supplied with the unit.
*2.Dot-dash lines indicate the control box boundaries.
*3.Refer to the Data book for connecting input/output signal connectors.
*4.Daisy-chain terminals (TB3) on the heat source units in the
same refrigerant system together
.
*5.Faston terminals have a locking function.
Make sure the terminals are securely locked in place after insertion.
Press the tab on the terminals to remove them.
*6.Control box houses high-voltage parts.
Before inspecting the inside of the control box,turn of
f the power
,
keep the unit of
f for at least 10 minutes, and confirm that the voltage
between FT
-P
and FT
-N on INV Board has dropped to DC20V or less.
*7.Refer to the Data book for wiring terminal block for
Pump Interlock and Operation ON signal.
LED1
Display
setting
Summary of Contents for PQHY-P120THMU-A
Page 1: ......
Page 11: ... 2 ...
Page 25: ... 16 ...
Page 83: ... 74 ...
Page 103: ... 94 III Heat source Unit Components GB HWE09080 ...
Page 105: ... 96 ...
Page 113: ... 104 IV Remote Controller GB HWE09080 ...
Page 115: ... 106 ...
Page 131: ... 122 ...
Page 143: ... 134 VI Refrigerant Circuit GB HWE09080 ...
Page 145: ... 136 ...
Page 181: ... 172 VII Control GB HWE09080 ...
Page 183: ... 174 ...
Page 235: ... 226 ...
Page 367: ... 358 ...
Page 414: ......