VIII
Test Run Mode ]
- 211 -
HWE09080
GB
4. Single
unit<PQRY>
(1) Cooling only operation
Item
Heat source unit model
PQRY-P72YHMU-A
PQRY-P96YHMU-A
Model name of BC controller
CMB-P104NU-G
CMB-P104NU-G
Operating
conditions
Indoor temperature
DB/WB
26.7°C/19.4°C
[80 °F/67 °F]
26.7°C/19.4°C
[80 °F/67 °F]
Heat source water temperature
°C [ °F]
29.4[85]
29.4[85]
Heat source water flow rate
m
3
/h
[G/h]
[gpm]
5.76
[1522]
[25.4]
5.76
[1522]
[25.4]
Indoor
unit
No. of connected units
Unit
2
2
No. of units in operation
2
2
Model
36/36
48/48
Pipe
length
Main pipe
m [ft]
5 [16-3/8]
5 [16-3/8]
Branch pipe
10 [32-3/4]
10 [32-3/4]
Total pipe length
25 [82]
25 [82]
Fan speed
Hi
Hi
Refrigerant charge
kg
[lbs-oz]
11.8 [27]
13.0 [29]
Heat source
unit
Current
A
17.7
23.3
Voltage
V
230
230
Compressor frequency
Hz
66
90
LEV opening
Indoor unit
Pulse
325/325
387/387
BC controller (1/2/3)
2000//160
2000//170
Pressure
switch
High pressure (63HS1)/
Low pressure (63LS)
MPa
[psi]
2.20/0.81
[319/117]
2.27/0.81
[329/117]
BC controller on the liquid side
(PS1)/Intermediate part (PS3)
2.10/2.10
[305/305]
2.17/2.17
[315/315]
Sectional
temperatures
Heat
source
unit
Discharge (TH4)
°C [ °F]
65 [149]
65 [149]
Heat exchanger outlet
33 [91]
34 [93]
Accumulator inlet
8 [46]
8 [46]
Accumulator outlet
8 [46]
8 [46]
Compressor inlet
19 [66]
19 [66]
Compressor shell bottom
47 [117]
40 [104]
Indoor
unit
LEV inlet
19 [66]
19 [66]
Heat exchanger outlet
6 [43]
6 [43]
Summary of Contents for PQHY-P120THMU-A
Page 1: ......
Page 11: ... 2 ...
Page 25: ... 16 ...
Page 83: ... 74 ...
Page 103: ... 94 III Heat source Unit Components GB HWE09080 ...
Page 105: ... 96 ...
Page 113: ... 104 IV Remote Controller GB HWE09080 ...
Page 115: ... 106 ...
Page 131: ... 122 ...
Page 143: ... 134 VI Refrigerant Circuit GB HWE09080 ...
Page 145: ... 136 ...
Page 181: ... 172 VII Control GB HWE09080 ...
Page 183: ... 174 ...
Page 235: ... 226 ...
Page 367: ... 358 ...
Page 414: ......