V
Electrical Wiring Diagram ]
- 110 -
HWE09080
GB
(4) PQRY-P72, 96, 120YHMU-A
(
)
+
-
+
+
+
+
1
2
+
+
+
+
+
*7
Solenoid valve
Symbol
Explanation
TH8
W
ater outlet temperature
THINV
Outlet temp.detect of heat exchanger for inverter
TB1
TB3
TB7
T
erminal
block
Central control transmission cable
Indoor/Heat source transmission cable
Power supply
TB8
TH4
TH5
TH7
THHS
Function setting connector
IGBT
temperature
W
ater inlet temperature
ACC inlet pipe temperature
Discharge pipe temperature
Operation ON signal, Pump Interlock
Thermistor
Z24,25
Explanation
Symbol
MF1
Fan motor(Radiator panel)
SV1a
SV4a,b,d
Heat exchanger capacity control
For opening/closing the bypass circuit under the O/S
LEVINV
Heat exchanger for inverter
SV7a,b
Heat exchanger capacity control
For opening/closing the bypass circuit
63HS1
SV9
21S4a
4-way valve
Explanation
Symbol
63H1
63LS
Pressure sensor
Pressure switch
High pressure protection for the heat source unit
High pressure
Low pressure
72C
Magnetic relay(inverter main circuit)
Current sensor(AC)
Crankcase heater(for heating the compressor)
CH1
1
CT12,22,3
Solenoid valve
Linear expansion valve
DCL
DC reactor
<Symbol explanation>
CNTYP
black
3
1
12
4
blue
CN63PW
t°
THINV
1
2
M
LEVINV
5
6
1
2
3
4
CNL
VE
purple
CN215
black
X12
5
6
1
CN509 blue
1
CN510 yellow
CNOUT1 yellow
6
5
4
*7
Operation
ON signal
Pump Interlock
3
1
TB8
2
34
red
orange
1
yellow
blue
4
2
1
1
X09
3
6
Ground
G
G
G
CN508 black
SV7a
Unit address
setting
CN504 green
CT12
C31
C33
CN5
red
D1
R5
Z5
Power Source
3~
60Hz
460V
SV7b
SV4b
1
3
white
T
ransformer box
X14
2
CN07
1
2
3
4
4
CN06
8
CNTR1
3
1
4
1
T02
(T
ransformer)
CNTR2
5
7
12
6
6
5
2
white
red
black
black
white
red
F4
AC 600V
3A
F
C8
F5
AC 600V
3A
F
red
CNIT
yellow
CNS2
t°
1
LED1
Display
setting
CN51
12V
Function
setting
SW1
10
1
CN992
yellow
CNTYP4
green
F4
AC250V
6.3A
T
R4
F3
F1
Z4
R2
F2
*3
3
2
Compressor ON/OFF output
Error detection output
CN201
Z25
1
4
1
1
1
TH8
Z3
1
Z2
U
ON
OFF
SW2
10
1
SWU2
LED1
4
C4
C35
C37
R31
R33
R30
ON
SW3
10
Control Board
TH7
CN40
63HS1
CN41
t
°t
TH4
3
2
2
2
1
SW5
LED3:Lit when powered
1
3
4
R32
2
Z1
1
1
DSA
C10
R34
R35
C36
3
C34
SC-V
CT22
SC-U
CN6
yellow
V
1
CN4
blue
red
1
1
t
L3
black
4
1
3
6
yellow
CN3K
*3
3
C3
TB21
C1
R3
CN1A
5
U
CN2
blue
CN3N
5
6
C7
U
4
4
R1
TB1
CN1B
3
TB7 Power selecting connector
CN102
3
2
1
2
1
U
TP1
6
L3
DCL
5
black
72C
white
red
3
2
1
ON
OFF
1
M-NET
power
supply circuit
1
2
3
C6
M-NET
Board
1
2
1
Power failure
detection circuit
1
CNAC2 black
CN502
5
Indoor/Outdoor
transmission
cable
INV Board
red
3
CNT01
TB23
L2
L1
1
ON
1
2
1's
digit
THHS
1
CNIT
red
S
2
1
1
CN990
1
W
TB3
10's
digit
OFF
LED2:CPU in operation
5
2
CNS2
yellow
TB7
1
CNDC
pink
M1
2
red
6
MS
3~
1
1
C100
*5
3
3
U
1
4
LED1:Power supply to
Indoor/Outdoor transmission line
X06
ZNR01
M2
32
M1
black
Central control
transmission
cable
*6
SC-L1
4
C2
C9
ON
C5
OFF
FT
-N
R5
CNAC4
Motor (Compressor)
5
2
3
3
1
CN04
red
4
CN2
3
CN4
X05
2
SV4d
3
SC-P2
P
1
CN21
1
CN202
red
TH5
°
N
CN1
M2
2
TP2
LED1:Normal operation(Lit)
/ Error(Blink)
2
CN503 blue
5
X04
4
*4
SC-W
U
C32
SC-L3
CH1
1
CN506
1
2
CN72
red
3
P
63H1
CN801
yellow
1
2
2
F1,F2,F3
AC250V
6.3A
T
2
1
OFF
SW4
10
black
1
CNT02
1
CN3D
4
3
2
1
21
CPU power
supply circuit
CNAC
red
2
1
F01
AC250V
3.15A
T
1
t
CN507 red
ON
OFF
10
SWU1
white
CN213
red
SC-L2
3
Z24
7
4
°
3
2
1
CNOUT2
yellow
2
1
3
1
4
white
3
red
21
CNPW
blue
1
CNTYP5
green
21S4a
U
X02
X03
5
1
3
7
CN4
CN6
°
IGBT
4
SC-P1
FT
-P
black
C30
red
Diode Bridge
CT3
72C
C1
CN2
R1
black
TB22
RSH1
CN102
3
R6
C17
1
1
RELA
Y
Board
63LS
ZNR1
U
L
Noise
Filter
L3
L2
L1
X08
3
1
3
SV4a
SV9
X07
75
CN83
3
5
6
460V
1
3
4
2
CNTR3
T03
(T
ransformer)
6
5
6
5
L3
L1
L2
L2
L2
L1
purple
460V
SV1a
CNTYP2
black
1
3
~
M
MF1
*1.Single-dotted lines indicate wiring not supplied with the unit.
*2.Dot-dash lines indicate the control box boundaries.
*3.Refer to the Data book for connecting
input/output signal connectors.
*4.Daisy-chain terminals (TB3) on the heat source units
in the same refrigerant system together
.
*5.Faston terminals have a locking function.
Make sure the terminals are securely locked in place after
insertion. Press the tab on the terminals to remove them.
*6.Control box houses high-voltage parts.
Before inspecting the inside of the control box,
turn of
f the power
,keep the unit of
f for at least 10 minutes,
and confirm that the voltage between FT
-P
and FT
-N
on INV Board has dropped to DC20V or less.
*7.Refer to the Data book for wiring terminal block for
Pump Interlock and Operation ON signal.
5
Summary of Contents for PQHY-P120THMU-A
Page 1: ......
Page 11: ... 2 ...
Page 25: ... 16 ...
Page 83: ... 74 ...
Page 103: ... 94 III Heat source Unit Components GB HWE09080 ...
Page 105: ... 96 ...
Page 113: ... 104 IV Remote Controller GB HWE09080 ...
Page 115: ... 106 ...
Page 131: ... 122 ...
Page 143: ... 134 VI Refrigerant Circuit GB HWE09080 ...
Page 145: ... 136 ...
Page 181: ... 172 VII Control GB HWE09080 ...
Page 183: ... 174 ...
Page 235: ... 226 ...
Page 367: ... 358 ...
Page 414: ......