FVXS-F

F l o o r   S t a n d i n g   U n i t

Air Conditioners

Technical Data

w w w . d a i k i n . e u

Summary of Contents for FVXS-F

Page 1: ...FVXS F F l o o r S t a n d i n g U n i t Air Conditioners Technical Data w w w d a i k i n e u ...

Page 2: ...FVXS F F l o o r S t a n d i n g U n i t Air Conditioners Technical Data w w w d a i k i n e u ...

Page 3: ...1 Features 2 2 Specifications 3 For indoor units only 3 Technical Specifications 3 Electrical Specifications 4 3 Dimensional drawing centre of gravity 5 Dimensional drawing 5 Centre of gravity 6 4 Piping diagram 7 5 Wiring diagram 8 Wiring diagram 8 6 Sound data 9 Sound pressure spectrum 9 ...

Page 4: ...ny interior décor and is more easy to clean Titanium apatite photocatalytic air purification filter Can be installed against a wall or recessed Dual air discharge flow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Lightweight but sturdy design optional 5 steps standard Titaniumapatite photocatalytic air purifica...

Page 5: ... Low m min 4 8 4 9 7 8 Silent Operation m min 4 1 4 5 6 6 Heating High m min 8 8 Medium m min 6 9 Low m min 5 0 Silent Operation m min 4 4 Fan Motor Quantity 1 1 1 Model D48D 28 Number of steps 5 5 5 Motor Speed cooling High rpm 640 650 800 Medium rpm 520 530 700 Low rpm 400 410 600 Silent Operation rpm 360 380 520 Speed heating High rpm 680 Medium rpm 550 Low rpm 420 Silent Operation rpm 380 Fan ...

Page 6: ...1 Item Drain hose Quantity 1 1 1 Item Air supply filter Quantity 1 1 1 Item Thermal insulation tape Quantity 2 2 2 2 3 Electrical Specifications FVXS25FV1B FVXS35FV1B FVXS50FV1B Power Supply Name V1 Phase 1 1 1 Frequency Hz 50 50 50 Voltage V 220 240 Current Nominal running current RLA Cooling A 0 13 0 13 0 17 Heating A 0 14 Maximum Running Current A 0 15 0 14 0 18 Wiring connections For Power Sup...

Page 7: ... 584 half concealed Wall hole Front panel fixed screws inside VP20 I D J20 O D J26 L 220 50 MIN 50 MIN Cooling dry A Model name label 95 Half concealed 85 Cool dry 3D056136 FVXS50F unit mm Main unit fixing screw Note 1 The mark Y shows piping direction Main unit fixed screws 666 half concealed Operation lamp Timer lamp Indoor unit ON OFF switch Signal receiver Air outlet selection switch Inside Na...

Page 8: ... Indoor units R 410A FVXS FV1B Split Sky Air Indoor units 6 3 Dimensional drawing centre of gravity 3 2 Centre of gravity FVXS25 50F 4D056197A ...

Page 9: ...exchanger Fan motor Field piping Field piping Refrigerant flow Cooling Heating Turbo fan Thermistor on heat exchanger Muffler assy 4D056137A FVXS50F Indoor unit Heat exchanger Fan motor Field piping Field piping Refrigerant flow Cooling Heating Turbo fan Thermistor on heat exchanger Muffler assy 4D056138A ...

Page 10: ... motor PCB1 PCB4 Printed circuit board R1T R2T Thermistor S1 S49 Connector S1W Operation switch S2W 4 Upward air flow limit switch S4W Air outlet selection switch X1M Terminal strip E3 Earth terminal heat ex E4 Earth terminal shield plate Signal receiver Infrared remote control Transmission circuit Rectifier CAUTION Note that operation will restart automatically if the main power supply is turned ...

Page 11: ...240V H 50Hz 220 240V L NOTE 1 Operation noise differs with operation and ambient conditions 2 Measure in anechoic room Location of microphone 3D056240A Octave band sound pressure level dB 0dB 0 0002 μ bar Octave band center frequency Hz FVXS35F Cooling approximate threshold hearing for continuous noise Legend 50Hz 220 240V H 50Hz 220 240V L NOTE 1 Operation noise differs with operation and ambient...

Page 12: ...240V H 50Hz 220 240V L NOTE 1 Operation noise differs with operation and ambient conditions 2 Measure in anechoic room Location of microphone 3D056238A Octave band sound pressure level dB 0dB 0 0002 μ bar Octave band center frequency Hz FVXS50F Heating approximate threshold hearing for continuous noise Legend 50Hz 220 240V H 50Hz 220 240V L NOTE 1 Operation noise differs with operation and ambient...

Page 13: ... 100 04 10 Copyright Daikin The present publication supersedes EEDEN09 100 Prepared in Belgium by Lannoo www lannooprint be a company whose concern for the environment is set in the EMAS and ISO 14001 systems Responsible Editor Daikin Europe N V Zandvoordestraat 300 B 8400 Oostende The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin E...