1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 13
1.3 Warning list
No.
Name
Detail
No.
Detail name
Stop
method
(Note 2,
3)
Process-
ing
system
(Note 5)
Stop
system
(Note 5)
Warning
Home position
return incomplete
warning
90.1 Home position return incomplete
90 90.2
Home position return abnormal
termination
90.5
Z-phase
unpassed
91
Servo amplifier
overheat warning
(Note 1)
91.1
Main circuit device overheat
warning
Common
92
Battery cable
disconnection
warning
92.1
Encoder battery cable
disconnection warning
Each
axis
92.3
Battery
degradation
Each
axis
93
ABS data transfer
warning
93.1
ABS data transfer requirement
warning during magnetic pole
detection
95.1 STO1 off detection
DB
Common All axes
95.2 STO2 off detection
DB
Common All axes
95 STO
warning
95.3
STO warning 1 (safety observation
function)
DB
95.4
STO warning 2 (safety observation
function)
DB
95.5
STO warning 3 (safety observation
function)
DB
96.1
In-position warning at home
positioning
Each
axis
96
Home position
setting warning
96.2
Command input warning at home
positioning
Each
axis
96.3
Servo off warning at home
positioning
96.4
Home positioning warning during
magnetic pole detection
97
Positioning
specification
warning
97.1
Program operation disabled
warning
97.2 Next station position warning
98
Software limit
warning
98.1
Forward rotation-side software
stroke limit reached
98.2
Reverse rotation-side software
stroke limit reached
99.1 Forward rotation stroke end off
(Note
4, 7)
99
Stroke limit warning
99.2 Reverse rotation stroke end off
(Note
4, 7)
99.4
Upper
stroke
limit off
(Note 7)
Each
axis
99.5 Lower stroke limit off
(Note 7)
Each
axis
9A
Optional unit input
data error warning
9A.1 Optional unit input data sign error
9A.2 Optional unit BCD input data error
9B
Error excessive
warning
9B.1 Excess droop pulse 1 warning
Each
axis
9B.3 Excess droop pulse 2 warning
Each
axis
9B.4
Error excessive warning during 0
torque limit
Each
axis
9C
Converter error
9C.1 Converter unit error
9D.1
Station number switch change
warning
9D
CC-Link IE warning
1
9D.2 Master station setting warning
9D.3
Overlapping station number
warning
9D.4
Mismatched station number
warning
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...