1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 55
Alarm No.: 46
Name: Servo motor overheat
Alarm content
The servo motor overheated.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
46.1 Abnormal
temperature of
servo motor 1
(1) Ambient temperature of
the servo motor has
exceeded 40
˚
C.
Check the ambient
temperature of the
servo motor.
It is over 40
˚
C.
Lower the ambient
temperature.
[A]
[B]
[WB]
[RJ010]
[GF]
It is less than 40
˚
C. Check
(2).
(2) Servo motor is
overloaded.
Check the effective
load ratio.
The effective load
ratio is high.
Reduce the load or
review the operation
pattern.
The effective load
ratio is small.
Check (3).
(3) The thermal sensor in
the encoder is
malfunctioning.
Check the servo motor
temperature when the
alarm occurs.
The servo motor
temperature is low.
Replace the servo
motor.
46.2 Abnormal
temperature of
servo motor 2
(1) Ambient temperature of
the linear servo motor
or direct drive motor
has exceeded 40
˚
C.
Check the ambient
temperature of the
linear servo motor or
direct drive motor.
It is over 40
˚
C.
Lower the ambient
temperature.
[A]
[B]
[WB]
[GF]
It is less than 40
˚
C. Check
(2).
(2) The linear servo motor
or direct drive motor
has been under
overload status.
Check the effective
load ratio.
The effective load
ratio is high.
Reduce the load or
review the operation
pattern.
The effective load
ratio is small.
Replace the servo
motor.
46.3 Thermistor
disconnected
error
(1) A thermistor wire is not
connected.
Check the thermistor
wire.
It is not connected.
Connect it correctly.
It is connected.
Check (2).
(2) The encoder cable MR-
ENECBL_M-H for HF-
JP series servo motors
is used for the HG-
JR22K1M(4) servo
motor.
Check the model of
the encoder cable.
MR-ENECBL_M-H
is used.
Change it to MR-
ENECBL_M-H-MTH.
MR-ENECBL_M-H-
MTH is used.
Check (3).
(3) The thermistor wire is
disconnected.
Check the thermistor
wire.
It is disconnected.
Repair the lead wire.
It is not
disconnected.
Replace the servo
motor.
46.4 Thermistor
circuit error
(1) A thermistor circuit of
the servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
46.5 Abnormal
temperature of
servo motor 3
Check it with the check method for [AL. 46.1].
46.6 Abnormal
temperature of
servo motor 4
(1) A current was applied to
the servo amplifier in
excess of its continuous
output current.
Check the effective
load ratio.
The effective load
ratio is high.
Reduce the load or
review the operation
pattern. Or use a
larger capacity
motor.
[A]
[B]
[WB]
[RJ010]
[GF]
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...