4. DRIVE RECORDER
4 - 10
4.2 How to display drive recorder information
Select "Diagnosis" and "Drive Recorder" from the
menu bar of MR Configurator2. The window
shown in the right hand image will be displayed.
(b)
(a)
(c)
(a) Click "Waveform" - "Display" to display the
graph preview window which shows data
before and after alarm occurrence.
For operating the graph preview window,
refer to Help of MR Configurator2.
(b) Click "Display" of Alarm onset data to
display each data at alarm occurrence.
(c) Click "History Clear" to delete all data at alarm occurrence recorded in the servo amplifier. After
clicking "History Clear", cycle the power of the servo amplifier. Note that the time to restart will be
longer than usual due to the deletion of the data.
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...