1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 11
No. Name
Detail
No.
Detail name
Stop
method
(Note
2, 3)
Alarm deactivation
Process-
ing
system
(Note 9)
Stop
system
(Note 9)
Alarm code (Note 8)
Alarm
reset
CPU
reset
Cycling
the
power
ACD3
(Bit 3)
ACD2
(Bit 2)
ACD1
(Bit 1)
ACD0
(Bit 0)
Alarm
84
Network module
initialization error
84.1
Network module undetected
error
DB
84.2
Network module initialization
error 1
DB
84.3
Network module initialization
error 2
DB
85
Network module
error
85.1 Network module error 1
SD
85.2 Network module error 2
SD
85.3 Network module error 3
SD
86
Network
communication
error
86.1 Network communication error 1
SD
86.2 Network communication error 2
SD
86.3 Network communication error 3
SD
8A
USB
communication
time-out error/serial
communication
time-out
error/Modbus-RTU
communication
time-out error
8A.1
USB communication time-out
error/serial communication
time-out error
SD
Common All axes
0 0 0 0
8A.2
Modbus-RTU communication
time-out error
SD
8D.1
CC-Link IE communication
error 1
SD
8D.2
CC-Link IE communication
error 2
SD
CC-Link IE
communication
error
8D.3 Master station setting error 1
DB
8D.5 Master station setting error 2
DB
8D
8D.6
CC-Link IE communication
error 3
SD
8D.7
CC-Link IE communication
error 4
SD
8D.8
CC-Link IE communication
error 5
SD
8D.9 Synchronization error 1
SD
8D.A Synchronization error 2
SD
8E.1
USB communication receive
error/serial communication
receive error
SD
Common
All
axes
8E.2
USB communication checksum
error/serial communication
checksum error
SD
Common
All
axes
8E
USB
communication
error/serial
communication
error/Modbus-RTU
communication
error
8E.3
USB communication character
error/serial communication
character error
SD
Common All axes
0 0 0 0
8E.4
USB communication command
error/serial communication
command error
SD
Common All axes
8E.5
USB communication data
number error/serial
communication data number
error
SD
Common All axes
8E.6
Modbus-RTU communication
receive error
SD
8E.7
Modbus-RTU communication
message frame error
SD
8E.8
Modbus-RTU communication
CRC error
SD
88888
Watchdog
8888._
Watchdog
DB
Common
All
axes
Summary of Contents for MELSERVO MR-J4-B-RJ Series
Page 7: ...2 MEMO ...
Page 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Page 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Page 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Page 171: ...MEMO ...